 浏览型号COM20022I3V-HD的Datasheet PDF文件第39页浏览型号COM20022I3V-HD的Datasheet PDF文件第40页浏览型号COM20022I3V-HD的Datasheet PDF文件第41页浏览型号COM20022I3V-HD的Datasheet PDF文件第42页浏览型号COM20022I3V-HD的Datasheet PDF文件第44页浏览型号COM20022I3V-HD的Datasheet PDF文件第45页浏览型号COM20022I3V-HD的Datasheet PDF文件第46页浏览型号COM20022I3V-HD的Datasheet PDF文件第47页  
10 Mbps ARCNET (ANSI 878.1) Controller with 2Kx8 On-Board RAM  
Datasheet  
Table 6.13 - Setup 2 Register  
SYMBOL DESCRIPTION  
BIT  
BIT NAME  
7
Read Bus Timing  
Select  
RBUSTMG This bit is used to Disable/Enable the High Speed CPU  
Read function for High Speed CPU bus support.  
RBUSTMG=0: Disable (Default), RBUSTMG=1: Enable.  
That is, if BUSTMG (pin 26) = 1 and RBUSTMG = 1, High  
Speed CPU Read operations are enabled. It does not  
influence write operation. High speed CPU Read operation  
is only for non-multiplexed bus.  
6
Reserved  
This bit is undefined.  
5,4 Clock Multiplier  
CKUP1, 0 Higher frequency clocks are generated from the 20 MHz  
crystal through the selection of these two bits as shown.  
This clock multiplier is powered-down on default. After  
changing the CKUP1 and CKUP0 bits, the ARCNET core  
operation is stopped and the internal PLL in the clock  
multiplier is awakened and it starts to generate the 40 MHz.  
The lock out time of the internal PLL is 8μSec typically.  
After 1 mS it is necessary to write command data '18H' to  
command register for re-starting the ARCNET core  
operation. EF bit must be ‘1’ if the data rate is over 5Mbps.  
CAUTION: Changing the CKUP1 and CKUP0 bits must be  
one time or less after releasing a hardware reset.  
CKUP1  
CKUP0  
Clock Frequency (Data Rate)  
20 MHz (Up to 2.5Mbps) Default  
40 MHz (Up to 5Mbps)  
Reserved  
0
0
1
1
0
1
0
1
80 MHz (Only 10Mbps)  
Note: After changing the CKUP1 or CKUP0 bits, it is  
necessary to write a command data '18H' to the  
command register. Because after changing the  
CKUP [1, 0] bits, the internal operation is stopped  
temporarily. The writing of the command is to start  
the operation.  
These initializing steps are shown below.  
1. Hardware reset (Power ON)  
2. Change CKUP[1, 0] bit  
3. Wait 1mSec (wait until stable oscillation)  
4. Write command '18H' (start internal operation)  
5. Start initializing routine (Execute existing software)  
3
2
Enhanced  
Functions  
EF  
This bit is used to enable the new enhanced functions in the  
COM20022I 3V. EF = 0: Disable (Default), EF = 1: Enable.  
If EF = 0, the timing and function is the same as in the  
COM20020, Revision B. See appendix “A”. EF bit must be  
‘1’ if the data rate is over 5Mbps.  
EF bit should be ‘1’ for new design customers.  
EF bit should be ‘0’ for replacement customers.  
No Synchronous  
NOSYNC  
This bit is used to enable the SYNC command during  
initialization. NOSYNC= 0, Enable (Default) The line must  
be idle for the RAM initialization sequence to be written.  
NOSYNC= 1, Disable:) The line does not have to be idle for  
the RAM initialization sequence to be written. See appendix  
“A”.  
SMSC COM20022I 3V  
Page 43  
Revision 02-27-06  
DATASHEET  