5Mbps ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM  
Datasheet  
Table 6.4 - Diagnostic Status Register  
BIT  
BIT NAME  
My Reconfiguration MY-  
RECON  
SYMBOL  
DESCRIPTION  
7
This bit, if high, indicates that a past reconfiguration was caused by this  
node. It is set when the Lost Token Timer times out, and should be  
typically read following an interrupt caused by RECON. Refer to the  
Improved Diagnostics section for further detail.  
6
Duplicate ID  
DUPID  
This bit, if high, indicates that the value in the Node ID Register matches  
both Destination ID characters of the token and a response to this token  
has occurred. Trailing zero's are also verified. A logic "1" on this bit  
indicates a duplicate Node ID, thus the user should write a new value into  
the Node ID Register. This bit is only useful for duplicate ID detection  
when the device is off line, that is, when the transmitter is disabled. When  
the device is on line this bit will be set every time the device gets the  
token. This bit is reset automatically upon reading the Diagnostic Status  
Register. Refer to the Improved Diagnostics section for further detail.  
5
4
3
Receive  
Activity  
RCVACT  
TOKEN  
This bit, if high, indicates that data activity (logic "1") was detected on the  
RXIN pin of the device. Refer to the Improved Diagnostics section for  
further detail.  
Token Seen  
This bit, if high, indicates that a token has been seen on the network, sent  
by a node other than this one. Refer to the Improved Diagnostic section  
for further detail.  
Excessive NAK  
EXCNAK  
This bit, if high, indicates that either 128 or 4 Negative Acknowledgements  
have occurred in response to the Free Buffer Enquiry. This bit is cleared  
upon the "POR Clear Flags" command. Reading the Diagnostic Status  
Register does not clear this bit. This bit, when set, will cause an interrupt  
if the corresponding bit in the IMR is also set. Refer to the Improved  
Diagnostics section for further detail.  
2
1
Tentative ID  
New Next ID  
TENTID  
This bit, if high, indicates that a response to a token whose DID matches  
the value in the Tentative ID Register has occurred. The second DID and  
the trailing zero's are not checked. Since each node sees every token  
passed around the network, this feature can be used with the device on-  
line in order to build and update a network map. Refer to the Improved  
Diagnostics section for further detail.  
NEW  
This bit, if high, indicates that the Next ID Register has been updated and  
that a node has either joined or left the network. Reading the Diagnostic  
Status Register does not clear this bit. This bit, when set, will cause an  
interrupt if the corresponding bit in the IMR is also set. The bit is cleared  
by reading the Next ID Register.  
NXTID  
1,0 (Reserved)  
These bits are undefined.  
Revision 12-05-06  
Page 32  
SMSC COM20020I Rev D  
DATASHEET  