5Mbps ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM  
Datasheet  
6.2.12 Setup 1 Register  
The Setup 1 Register is a read/write 8-bit register accessed when the Sub Address Bits are set up  
accordingly (see the bit definitions of the Configuration Register). The Setup 1 Register allows the user to  
change the network speed (data rate) or the arbitration speed independently, invoke the Receive All  
feature and change the nPULSE1 driver type. The data rate may be slowed to 156.25Kbps and/or the  
arbitration speed may be slowed by a factor of two. The Setup 1 Register defaults to the value 0000 0000  
upon hardware reset only.  
6.2.13 Setup 2 Register  
The Setup 2 Register is new to the COM20020ID. It is an 8-bit read/write register accessed when the Sub  
Address Bits SUBAD[2:0] are set up accordingly (see the bit definitions of the Sub Address Register). This  
register contains bits for various functions. The CKUP1,0 bits select the clock to be generated from the 20  
MHz crystal. The RBUSTMG bit is used to Disable/Enable Fast Read function for High Speed CPU bus  
support. The EF bit is used to enable the new timing for certain functions in the COM20020ID (if EF = 0,  
the timing is the same as in the COM20020 Rev. B). See Appendix A. The NOSYNC bit is used to enable  
the NOSYNC function during initialization. If this bit is reset, the line has to be idle for the RAM  
initialization sequence to be written. If set, the line does not have to be idle for the initialization sequence  
to be written. See Appendix A, pg 68.  
The RCNTM[1,0] bits are used to set the time-out period of the recon timer. Programming this timer for  
shorter time periods has the benefit of shortened network reconfiguration periods. The time periods shown  
in the table on the following page are limited by a maximum number of nodes in the network. These time-  
out period values are for 5Mbps. For other data rates, scale the time-out period time values accordingly;  
the maximum node count remains the same.  
TIME-OUT  
PERIOD  
MAX NODE  
COUNT  
RCNTM1 RCNTM0  
0
0
1
1
0
1
0
1
420 mS  
Up to 255 nodes  
Up to 64 nodes  
Up to 32 nodes  
Up to 16 nodes  
Note 6.3  
105 mS  
52.5 mS  
26.25 mS*  
Note 6.3  
The node ID value 255 must exist in the network for the 26.25 mS time-out to be valid.  
Revision 12-05-06  
Page 30  
SMSC COM20020I Rev D  
DATASHEET  