 浏览型号SX1232的Datasheet PDF文件第69页浏览型号SX1232的Datasheet PDF文件第70页浏览型号SX1232的Datasheet PDF文件第71页浏览型号SX1232的Datasheet PDF文件第72页浏览型号SX1232的Datasheet PDF文件第74页浏览型号SX1232的Datasheet PDF文件第75页浏览型号SX1232的Datasheet PDF文件第76页浏览型号SX1232的Datasheet PDF文件第77页  
SX1232  
WIRELESS & SENSING  
DATASHEET  
Name  
(Address)  
Default  
value  
Bits  
Mode  
Variable Name  
Description  
Packet Handling registers  
RegPreambleMsb 7-0  
(0x25)  
PreambleSize(15:8)  
PreambleSize(7:0)  
AutoRestartRxMode  
rw  
rw  
rw  
0x00 Size of the preamble to be sent (from TxStartCondition  
fulfilled). (MSB byte)  
RegPreambleLsb 7-0  
(0x26)  
0x03 Size of the preamble to be sent (from TxStartCondition  
fulfilled). (LSB byte)  
RegSyncConfig  
(0x27)  
7-6  
0x02 Controls the automatic restart of the receiver after the  
reception of a valid packet (PayloadReady or CrcOk):  
00 Æ Off  
01 Æ On, without waiting for the PLL to re-lock  
10 Æ On, wait for the PLL to lock (frequency changed)  
11 Æ reserved  
5
4
PreamblePolarity  
SyncOn  
rw  
rw  
0x00  
0x01  
Sets the polarity of the Preamble  
0 Æ 0xAA (default)  
1 Æ 0x55  
Enables the Sync word generation and detection:  
0 Æ Off  
1 Æ On  
3
FifoFillCondition  
rw  
0x00  
0x03  
FIFO filling condition:  
0 Æ if SyncAddress interrupt occurs  
1 Æ as long as FifoFillCondition is set  
2-0  
7-0  
SyncSize  
rw  
rw  
Size of the Sync word:  
(SyncSize + 1) bytes, (SyncSize) bytes if ioHomeOn=1  
1st byte of Sync word. (MSB byte)  
Used if SyncOn is set.  
RegSyncValue1  
(0x28)  
SyncValue(63:56)  
0x01  
*
2nd byte of Sync word  
Used if SyncOn is set and (SyncSize +1) >= 2.  
RegSyncValue2  
(0x29)  
7-0  
7-0  
7-0  
7-0  
7-0  
7-0  
7-0  
SyncValue(55:48)  
SyncValue(47:40)  
SyncValue(39:32)  
SyncValue(31:24)  
SyncValue(23:16)  
SyncValue(15:8)  
SyncValue(7:0)  
rw  
rw  
rw  
rw  
rw  
rw  
rw  
0x01  
*
3rd byte of Sync word.  
Used if SyncOn is set and (SyncSize +1) >= 3.  
RegSyncValue3  
(0x2a)  
0x01  
*
4th byte of Sync word.  
Used if SyncOn is set and (SyncSize +1) >= 4.  
RegSyncValue4  
(0x2b)  
0x01  
*
5th byte of Sync word.  
Used if SyncOn is set and (SyncSize +1) >= 5.  
RegSyncValue5  
(0x2c)  
0x01  
*
6th byte of Sync word.  
Used if SyncOn is set and (SyncSize +1) >= 6.  
RegSyncValue6  
(0x2d)  
0x01  
*
th byte of Sync word.  
RegSyncValue7  
(0x2e)  
0x01  
*
7
Used if SyncOn is set and (SyncSize +1) >= 7.  
8th byte of Sync word.  
Used if SyncOn is set and (SyncSize +1) = 8.  
RegSyncValue8  
(0x2f)  
0x01  
*
Rev 3 - August 2012  
Page 73  
www.semtech.com  
 复制成功!