In order to determine the best starting value for Rset, the following formula should be  
used:  
Rset = 8*(Rtrm/VoutppSE)  
Where VoutppSE is in volts (V), and both resistances are in ohms (Ω).  
Rtrm is the value of the termination resistors, which should be equal to the  
characteristic impedance of the cable, and is typically 75Ω.  
The cable must be short (1m), and terminated at both ends for the formula to be valid.  
Example: For a 75Ω cable, Rtrm = 75Ω (at both ends), VoutppSE = 800mV  
Rset = 8*(75/0.8) = 750Ω  
This formula is not valid for long, unterminated, or improperly terminated cables.  
This formula should be considered as a starting point, and actual swing values may vary  
based on layout. Also, for large output swings (>1040mV), smaller Rset values may be  
required in order to achieve the desired output swing level at HD and 3G data rates.  
Table 4-5: Typical RSET Values  
Output Swing (mV)  
RSET (Ω)  
1800*  
800  
332  
750  
500  
1210  
*Note: In order to generate output swings greater than 1040mV, VCC_TERM must be connected to a 5V  
supply.  
4.7 Output Return Loss Measurement  
The GS2988 has a feature which allows users to measure ORL reliably while the device is  
still powered. The device can be put into a Balance mode which prevents the outputs  
from toggling while the device is powered on, allowing the ORL to be measured while  
the device is still powered.  
When EQ_EN is LOW, while SD/HD is HIGH, the device goes into Balance mode. This  
mode is used during ORL measurement, disabling the AC signal path of the device  
without powering it down. When in Balance mode, the device produces equal  
pull-down currents in both differential shoulders of the serial data differential output,  
effectively stopping the output at the output common mode voltage level. Semtech  
recommends using Balance mode when measuring ORL with 2.5V termination voltage.  
GS2988  
Final Data Sheet  
13 of 18  
Semtech  
www.semtech.com  
Rev.6  
GENDOC-052131 July 2015  