8.14 Analog Turn-On Control
0x15 [default 0XB4]
Address
Name
Bits
R/W
Description
-
7..6
r/w
Reserved, always set to 10b
Analog circuitry turn-on time (Burst Mode only):
00 → 0 µs
01 → 10 µs
0X15
ANA_ON
5..4
3..0
r/w
r/w
10 → 20 µs
11 → 40 µs
Note: default value is suitable for most applications
-
Reserved, always set to 0100b
Table 36
8.15 Reserved
Do not write to configuration register address 0x16. It should retain its power-on default value.
8.16 Option Control
0x17 – [default 22h]
Address
Name
Bits
7..2
R/W
Description
-
r/w
Reserved, always set to 0010 00b
Active edge for INT pin (Burst Mode only):
0 → Falling edge active (active low)
1 → Rising edge active (active high)
LVLINT
1
0
r/w
r/w
0X17
Active edge for DRSSI pin (Continuous Mode only):
0 → Falling edge active (active low)
LVLDRSSI
1 → Rising edge active (active high)
Table 37
8.17 Reserved
Do not write to configuration registers addresses 0x18 and higher, except as discussed in Section 8.18.
8.18 Default Overrides for Enhanced Performance
TRC104 operation can be enhanced by overriding several default values in register addresses shown in Table 38.
These override values should be written before the TRC104 is first placed in a transmit or receive mode.
Register Address
Power-on Default
0X30
Default Override
0XB0
0X06
0X2C
0X39
0X4F
0X77
0X19
0X18
0XBB
0XB9
0X26
0X66
0X7C
0X5C
Table 38
www.RFM.com E-mail: info@rfm.com
©2009 by RF Monolithics, Inc.
Technical support +1.800.704.6079
Page 28 of 33
TRC104 - 08/13/09