M61880FP
Electrical Characteristics
(Unless specified otherwise noted, VCC = 5 V ±5%, Ta = -20ºC to +70ºC)
Limits
Item
Symbo Min.
l
Typ.
Max.
Unit
Test Conditions
“H” input voltage DATA
ENB, S/H
VIH
2.0
2.0
V
V
V
V
V
“L” input voltage
DATA
ENB, S/H
Vr
VIL
0.8
0.8
2.0
Reference
Vr
0.35
1.4
1.5
voltage input
Reference
Vref
Vref
1.5
1.6
V
Io = ±10µA
voltage output
Temperature
coefficient
0.1
mV/°C Ta = −20 to 25°C
Ta = 25 to 70°C
−0.1
Operating
voltage range
LD
VLD
VI
2.5
Vcc
V
V
V
V
ILD = 75mA
Effective voltage CH
upper limit
2.7
3.0
“H” output
voltage
CH
VOH
VOL
II
Vcc−1.6
ENB = “L”, IOH = (−0.6mA)
ENB = “L”, IOL = (0.6mA)
“L” output
voltage
CH
0.6
20
Input voltage
DATA, ENB
µA
VI = 2.7V
−0.2
mA
mA
VI = 0.4V
Switching
current (Note)
LD
LD
CH
CH
CH
LD
Isw
IB
75
CH = 3.5V, Rs = 1.2kΩ, VLD = 3V
Bias current
(Note)
20
mA
VB = 1.4V, RB = 70kΩ, VLD = 3V
ENB = “L”, Vo = (0.6 to Vcc−1.6V)
ENB = “L”, Vo = (0.6 to Vcc−1.6V)
Vo = 2.0 to 3.0V, hold state
Load charge
current
Icg
−0.2
0.66
−0.5
−0.1
1.0
−0.66 mA
Load discharge
current
Idg
Ioz
2.0
0.5
mA
Off-state output
current
µA
Off output
current
LOFF
50
50
63
63
µA
µA
mA
ENB = “L”, DATA = “H”, Isw = 50mA
ENB = “H”, DATA = “L”, Isw = 50mA
Vcc = 5.25V, ENB = DATA = 0V
Power supply
current
Icc
43
43
0V, CH = 2.5V,
DATA = 4.5V
VB = 1.5V, Rs =
820Ω, RB = 75 Ω
Ro = LD = 5.0V
* Reference values are values when Ta = 25ºC and VCC = 5 V.
Note: These items indicate input voltage/output current conversion characteristics. The M61880 should be used with
ISW and IB within the Specification Value range given in “Recommended Operating Conditions.”
Rev.1.0, Sep.19.2003, page 8 of 20