 浏览型号HD64F3337YF16的Datasheet PDF文件第270页浏览型号HD64F3337YF16的Datasheet PDF文件第271页浏览型号HD64F3337YF16的Datasheet PDF文件第272页浏览型号HD64F3337YF16的Datasheet PDF文件第273页浏览型号HD64F3337YF16的Datasheet PDF文件第275页浏览型号HD64F3337YF16的Datasheet PDF文件第276页浏览型号HD64F3337YF16的Datasheet PDF文件第277页浏览型号HD64F3337YF16的Datasheet PDF文件第278页  
Bit 6—Receive Data Register Full (RDRF): This bit indicates when one character has been  
received and transferred to RDR.  
Bit 6: RDRF  
Description  
0
To clear RDRF, the CPU must read RDRF after it has been set to 1, then write  
a 0 in this bit.  
(Initial value)  
1
This bit is set to 1 when one character is received without error and transferred  
from RSR to RDR.  
Bit 5—Overrun Error (ORER): This bit indicates an overrun error during reception.  
Bit 5: ORER  
Description  
0
To clear ORER, the CPU must read ORER after it has been set to 1, then write  
a 0 in this bit.  
(Initial value)  
1
This bit is set to 1 if reception of the next character ends while the receive data  
register is still full (RDRF = 1).  
Bit 4—Framing Error (FER): This bit indicates a framing error during data reception in  
asynchronous mode. It has no meaning in synchronous mode.  
Bit 4: FER  
Description  
0
To clear FER, the CPU must read FER after it has been set to 1, then write a 0  
in this bit.  
(Initial value)  
1
This bit is set to 1 if a framing error occurs (stop bit = 0).  
Bit 3—Parity Error (PER): This bit indicates a parity error during data reception in the  
asynchronous mode, when a communication format with parity bits is used.  
This bit has no meaning in the synchronous mode, or when a communication format without  
parity bits is used.  
Bit 3: PER  
Description  
0
To clear PER, the CPU must read PER after it has been set to 1, then write a 0  
in this bit.  
(Initial value)  
1
This bit is set to 1 when a parity error occurs (the parity of the received data  
does not match the parity selected by the O/E bit in SMR).  
244  