TIMER A  
7.5 One-shot pulse mode  
7.5 One-shot pulse mode  
In this mode, the timer outputs a pulse which has an arbitrary width once.  
When a trigger occurs, the timer outputs “H” level from the TAiOUT pin for an arbitrary time. Table 7.5.1 lists  
the specifications of the one-shot pulse mode. Figure 7.5.1 shows the structures of the timer Ai register and  
timer Ai mode register in the one-shot pulse mode.  
Table 7.5.1 Specifications of one-shot pulse mode  
Item  
Specifications  
Count source f  
i
f
1
, f  
2
, f16, f64, f512, or f4096  
Count operation  
Countdown  
When the counter value becomes “000016,” reload register’s con-  
tents are reloaded, and counting stops.  
If a trigger occurs during counting, reload register’s contents are  
reloaded, and counting continues.  
Output pulse width (“H”)  
Count start condition  
Count stop condition  
n
[s] n : Timer Ai register’s set value  
f
i
When a trigger occurs. (Note)  
Internal or external trigger can be selected by software.  
When the counter value becomes “000016  
When the count start bit is cleared to “0”  
When counting stops.  
Interrupt request occurrence timing  
TAiIN pin’s function  
Programmable I/O port pin or trigger input pin  
One-shot pulse output  
TAiOUT pin’s function  
Read from timer Ai register  
Write to timer Ai register  
An undefined value is read out.  
While counting is stopped  
When a value is written to timer Ai register, it is written to both of  
the reload register and counter.  
While counting is in progress  
When a value is written to timer Ai register, it is written only to the  
reload register. (Transferred to counter at the next reload timing.)  
Note: The trigger is generated with the count start bit = “1.”  
7905 Group User’s Manual Rev.1.0  
7-29  
 复制成功!