5
Absolute Maximum Ratings
Stresses beyond those listed may cause permanent damage to the DPM. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability. Functional operation of the DPM at absolute maximum
ratings or conditions beyond those indicated in the operational sections of this specification is not implied.
Parameter
Ambient Temperature Range
Storage Temperature (Ts)
Junction Temperature (TJ)
Input Voltage
Conditions/Description
Min
-40
-55
Max
85
Units
°C
150
°C
125
°C
VDD pin
Any pin other than VDD
DC
-0.3
-0.5
3.6
VDC
VDC
mA
Input Voltage
VDD+0.5
40
Pin Current
6
7
Mechanical Specifications
Parameter
Peak Reflow Temperature
Lead Plating
Conditions/Description
Min
Nom
Max
Units
40 sec maximum duration
260
°C
100% matte tin
3
Moisture Sensitivity Level
JEDEC J-STD-020C
Reliability Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
Demonstrated at 55°C,
60% Confidence Level
Failure Rate
2.26
FIT
Read-
Write
cycles
Non-Volatile Memory Endurance
-40°C to 85°C ambient
10,000
ZD-00896 Rev. 5.2, 9-Apr-13
www.power-one.com Page 4 of 36