欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7350-PI 参数 Datasheet PDF下载

PM7350-PI图片预览
型号: PM7350-PI
PDF下载: 下载PDF文件 查看货源
内容描述: 双串行链路物理层复用器 [DUAL SERIAL LINK PHY MULTIPLEXER]
分类和应用: 复用器ATM集成电路SONET集成电路SDH集成电路电信集成电路电信电路异步传输模式
文件页数/大小: 241 页 / 1939 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7350-PI的Datasheet PDF文件第194页浏览型号PM7350-PI的Datasheet PDF文件第195页浏览型号PM7350-PI的Datasheet PDF文件第196页浏览型号PM7350-PI的Datasheet PDF文件第197页浏览型号PM7350-PI的Datasheet PDF文件第199页浏览型号PM7350-PI的Datasheet PDF文件第200页浏览型号PM7350-PI的Datasheet PDF文件第201页浏览型号PM7350-PI的Datasheet PDF文件第202页  
RELEASED  
PM7350 S/UNI-DUPLEX  
DATA SHEET  
PMC-1980581  
ISSUE 5  
DUAL SERIAL LINK PHY MULTIPLEXER  
SCI-PHY/Utopia16-bit master:  
SCI-PHY/Utopia16-bit slave:  
Any-PHY 16-bit slave:  
54B (base cell + UDF)  
54B (base cell + UDF)  
56B (base cell + UDF + 2 address)  
The similar output port default configuration produces the following cell  
lengths:  
SCI-PHY/Utopia 8-bit master:  
SCI-PHY 8-bit slave:  
53B  
54B (base cell + address)  
54B (base cell + address)  
54B (base cell + UDF)  
56B (base cell + 2 address)  
56B (base cell + UDF + 2 address)  
Any-PHY 8-bit slave:  
SCI-PHY/Utopia16-bit master  
SCI-PHY16-bit slave:  
Any-PHY16-bit slave:  
In Table 19 to Table 23, these would be referred as 53/53/54(54/54/56) and  
53/54/54(54/54/56) byte bus length.  
When the input side is configured as a 8-bit parallel bus or as a clocked serial  
data interface and the output side is configured as a 16-bit parallel bus, the  
UDF is undefined at the far end independently of the LVDS link configuration.  
When the input side is configured as a 16-bit parallel bus and the output side  
is configured as a 8-bit parallel bus or as a clocked serial data interface, the  
UDF is stripped at the far end.  
When using the CSD (Clock Serial Data interface), the cell size is fixed at 53  
bytes. By default, cell delineation is enable on the Clocked Serial Data  
receive port (Receive Serial Indirect Channel Configuration register 0x69,  
DDELIN=0). The HCS value is used only to acquire and maintain cell  
delineation and does not need to be carried to the other side. Similarly, by  
default the HCS value is generated by the Clock Serial Data transmit  
interface (Transmit Serial Indirect Channel Data register 0x71, DHCS=0) and  
does need to be carried over the LVDS link.  
When unframed data is transported through the Clocked Serial Data  
interface, data is packet in 53 byte packet and carried transparently. All five  
fields of the cell header are used and must be carried.  
For control cells written or read via the microprocessor port, bytes 0&1  
correspond to the microprocessor port’s unique PHY address field. However  
since this field is fixed there is no useful information in these bytes. Bytes  
10&11 are always undefined. Bytes 2&3 correspond to the user prepend  
bytes, and bytes 8&9 correspond to the H5&HDF bytes.  
The PHY address field is transported across the LVDS in an extra word  
added to each user cell. Therefore it is not necessary that the H5 (H5/UDF)  
field be sent over the LVDS link even if the output bus interfaces is  
configured to embed the PHY address in the H5 (H5/UDF) field. This will  
slightly increase the effective throughput of the LVDS, but it will impact control  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
186  
 复制成功!