PM7350 S/UNI-DUPLEX  
DATA SHEET  
PMC-1980581  
ISSUE 5  
DUAL SERIAL LINK PHY MULTIPLEXER  
parallel bus, master bus mode or clocked serial data). Refer to the S/UNI-  
VORTLEX datasheet for details.  
The parallel bus of the S/UNI-DUPLEX is fully compliant to Utopia Level 2  
bus protocol only when configured as a bus master. In this case, cell length is  
either 53 bytes or 27 16-bit words depending if the interface bus width is set  
to 8 or 16 bit.  
When used as a bus slave, the parallel bus input and output ports can  
operate in SCI-PHY or Any-PHY mode. When configured as a SCI-PHY bus  
slave, the input port can be remains compliant to Utopia Level 2 (default  
setting), but the output port becomes a proxy, a single addressable PHY  
carrying the cell traffic for up to the 32 PHYs. The PHY ID is encoded in a  
system prepend byte or 16-bit word (depending if the interface bus width is  
set to 8 or 16 bit). To keep the cell compatible with Utopia Level 2 format, the  
PHY ID can be routed in the H5 (H5/UDF for 16-bit bus) field of the cell by  
setting the INADDUDF bit of the SCI-PHY/Any-PHY Output Configuration  
register to logic 1.  
When operating in SCI-PHY (master or slave mode) or in Any-PHY slave  
mode, prepend words can be added to the cell, up to two bytes for the 8-bit  
(PRELEN[1:0]=0b10) cell format and one word in 16-bit (PRELEN[1:0]=0b01)  
cell format. The H5 (H5/UDF) field of the cell can be omitted as determined  
by setting the H5UDF of the SCI-PHY/Any-PHY Input Configuration 1 and  
SCI-PHY/Any-PHY Output Configuration registers to logic 0.  
Both input and output parallel interface can operate in Any-PHY mode,  
meaning Any-PHY bus timing and addressing must be used. Setting the  
INADDUDF bit of the register SCI-PHY/Any-PHY Output Configuration  
register to 1 when the bus is configured as Any-PHY has no effect. Although  
the S/UNI-DUPLEX only supports 32 logic channels, it is possible to specify  
the base address of the input port in a larger addressing range with the  
Extended Address Match and Extended Address Mask registers. The value of  
the Extended Address Match register is also appended to the PHY ID of cells  
read from the output port.  
For a given configuration set by the values of the H5UDF, INADDUDF and  
PRELEN[1:0], cell length may vary depending of the mode of the parallel bus,  
determined by the value of the IMASTER, IBUS8, IANYPPHY, OMASTER,  
OBUS8 and OANYPHY inputs. The following is an example of the various cell  
lengths produced by the input port default configuration (H5UDF=1,  
PRELEN[1:0]=00):  
SCI-PHY/Utopia 8-bit master:  
SCI-PHY/Utopia 8-bit slave:  
Any-PHY 8-bit slave:  
53B  
53B  
54B (base cell + address)  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
185  