11.7 RIPP Registers
Register 0x200: RIPP Control
Bit Type Function
15 R/W
Default
RIPP_EN
Reserved
RIPP_BUSY
Reserved
0
0
0
0
14
13
R
12:0
RIPP_BUSY
This is a status signal indicating that the RIPP main-state machine is currently active. This
bit is generated by RIPP.
RIPP_EN
The RIPP_EN enables the RIPP main state machine for normal operations. When RIPP_EN
= 0 and RIPP_BUSY = 0, all RIPP operations are disabled. The RIPP_EN should be set to a
‘1’ for normal operations after the initialization of RIPP context memory.
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC-2020889, Issue 2
149