S/UNI®-JET Data Sheet  
Released  
Pin Name  
Type  
Pin  
No.  
Function  
RPOHCLK  
Output  
W13  
The Receive PLCP Overhead Clock (RPOHCLK) is  
active when PLCP processing is enabled. The frequency  
of this signal depends on the selected PLCP format.  
RPOHCLK is nominally a 26.7 kHz clock for a DS1 PLCP  
frame, a 768 kHz clock for a DS3 PLCP frame, a 33.7  
kHz clock for an E1 based PLCP frame, or a 576 kHz  
clock for a G.751 E3 based PLCP frame.  
RPOHFP and RPOH are updated on the falling edge of  
RPOHCLK.  
RSCLK  
The Framer Recovered Clock (RSCLK) is valid when the  
S/UNI-JET is configured as a DS3, E3, or J2 framer for  
non-ATM applications by setting the FRMRONLY bit in  
the S/UNI-JET Configuration Register.  
RSCLK is the recovered clock and timing reference for  
RDATO, RFPO/RMFPO, and ROVRHD.  
The Framer Recovered Gapped Clock (RGAPCLK) is  
valid when the S/UNI-JET is configured as a DS3, E3, or  
J2 framer for non-ATM applications by setting the  
FRMRONLY bit in the S/UNI-JET Configuration 1  
Register and the RXGAPEN bit in the S/UNI-JET  
Configuration 2 Register.  
RGAPCLK  
RGAPCLK is the recovered clock and timing reference  
for RDATO. RGAPCLK is held high for bit positions  
which correspond to overhead.  
LCD  
Output  
Y14  
The Loss of Cell Delineation (LCD) is an active high  
signal which is asserted while the ATM cell processor  
has detected a Loss of Cell Delineation defect. The  
FRMRONLY bit in the S/UNI-JET Configuration 1  
Register must be set to logic zero for LCD to be valid.  
The Framer Receive Data (RDATO) is valid when the  
S/UNI-JET is configured as a DS3, E3, or J2 framer for  
non-ATM applications by setting the FRMRONLY bit in  
the S/UNI-JET Configuration 1 Register.  
RDATO  
RDATO is the received data aligned to RFPO/RMFPO  
and ROVRHD. RDATO is updated on the active edge (as  
set by the RSCLKR register bit) of RSCLK or RGAPCLK.  
FRMSTAT  
Output  
Input  
U1  
Framer Status (FRMSTAT) is an active high signal that  
can be configured to show when one of the J2, E3, DS3,  
or PLCP framers have detected certain conditions. The  
FRMSTAT output can be programmed via the  
STATSEL[2:0] bits in the S/UNI-JET Configuration 2  
Register to indicate: E3/DS3 LOF or J2 extended LOF,  
E3/DS3 OOF or J2 LOF, PLCP LOF, PLCP OOF, AIS,  
LOS, and DS3 Idle. FRMSTAT should be treated as a  
“glitch-free” asynchronous signal.  
ATM8  
L18  
The ATM Interface Bus Width Selection (ATM8) input pin  
determines whether the S/UNI-JET works with a 8-bit  
wide interface (RDAT[7:0] and TDAT[7:0]) or a 16-bit  
wide interface (RDAT[15:0] and TDAT[15:0]).  
If ATM8 is set to logic one, then the 8-bit wide interface is  
chosen. If ATM8 is set to logic zero, then the 16-bit wide  
interface is chosen.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990267, Issue 3  