S/UNI®-JET Data Sheet
Released
RPLDMIE
The receive payload type label mismatch interrupt enable bit (RPLDMIE) controls the
activation of the interrupt output when the comparison between received and the expected
payload type label changes state from match to mismatch and vice versa. When RPLDMIE is
set high, changes in match state activates the interrupt output. When RPLDMIE is set low,
changes from match to mismatch or mismatch to match will not generate an interrupt.
RPLDUIE
The receive payload type label unstable interrupt enable bit (RPLDUIE) controls the
activation of the interrupt output when the received payload type label changes state from
stable to unstable and vice versa. When RPLDUIE is set high, changes in stable state
activates the interrupt output. When RPLDUIE is set low, changes in the stable state will not
generate and interrupt.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990267, Issue 3
229