S/UNI®-JET Data Sheet  
Released  
Register 390H: TTB Control  
Bit  
Type  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Function  
ZEROEN  
RRAMACC  
RTIUIE  
RTIMIE  
PER5  
TNULL  
NOSYNC  
Reserved  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
0
0
0
0
0
1
0
0
Reserved  
The reserved bit should be set to logic zero for proper operation.NOSYNC  
The NOSYNC bit disables synchronization to the Trail Trace message. When NOSYNC is set  
high, synchronization is disabled and the bytes of the Trail Trace message are captured by the  
TTB in a circular buffer. When NOSYNC is set low, the TTB synchronizes to the byte with  
the most significant bit set high and places that byte in the first location in the capture buffer  
page.  
TNULL  
The transmit null (TNULL) bit controls the insertion of all-zeros into the outgoing Trail Trace  
message. The null insertion should be used when microprocessor accesses that change the  
outgoing trail trace message are being performed. When TNULL is set high, an all-zeros byte  
is inserted to the transmit stream. When this bit is set low, the contents of the transmit trace  
buffer are sent.  
PER5  
The receive trace identifier persistency bit (PER5) controls the number of times that  
persistency check is made in order to accept the received message. When this bit is set high,  
five identical message required in order to accept the message. When this bit set low, three  
unchanged consecutive messages are required.  
RTIMIE  
The receive trace identifier mismatch interrupt enable (RTIMIE) controls the activation of the  
interrupt output when comparison between the accepted trace identifier message and the  
expected trace identifier message changes state from match to mismatch and vice versa.  
When RTIMIE is set high, changes in match state will activate the interrupt output. When  
RTIMIE set low, trail trace message match state changes will not affect INTB.  