欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7347-BI 参数 Datasheet PDF下载

PM7347-BI图片预览
型号: PM7347-BI
PDF下载: 下载PDF文件 查看货源
内容描述: SATURN用户网络接口的J2 / E3 / T3 [SATURN USER NETWORK INTERFACE for J2/E3/T3]
分类和应用: 网络接口
文件页数/大小: 341 页 / 1733 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7347-BI的Datasheet PDF文件第220页浏览型号PM7347-BI的Datasheet PDF文件第221页浏览型号PM7347-BI的Datasheet PDF文件第222页浏览型号PM7347-BI的Datasheet PDF文件第223页浏览型号PM7347-BI的Datasheet PDF文件第225页浏览型号PM7347-BI的Datasheet PDF文件第226页浏览型号PM7347-BI的Datasheet PDF文件第227页浏览型号PM7347-BI的Datasheet PDF文件第228页  
S/UNI®-JET Data Sheet  
Released  
Register 391H: TTB Trail Trace Identifier Status  
Bit  
Type  
R
Function  
BUSY  
Unused  
Unused  
Unused  
RTIUI  
RTIUV  
RTIMI  
RTIMV  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
X
X
X
X
X
X
X
X
R
R
R
R
RTIMV  
The receive trace identifier mismatch value status bit (RTIMV) is set high when the accepted  
message differs from the expected message. RTIMV is set low when the accepted message is  
equal to the expected message. A mismatch is not declared if the accepted trail trace message  
string is all-zeros.  
RTIMI  
The receive trace identifier mismatch indication status bit (RTIMI) is set high when  
match/mismatch status of the trace identifier framer changes state. This bit (and the interrupt)  
is cleared when this register is read.  
RTIUV  
The receive trace identifier unstable value status bit (RTIUV) is set high when eight messages  
that differ from its immediate predecessor are received. RTIUV is set low and the unstable  
message count is reset when three or five (depending on PER5 control bit) consecutive  
identical messages are received.  
RTIUI  
The receive trace identifier unstable indication status bit (RTIUV) is set high when the  
stable/unstable status of the trace identifier framer changes state. This bit (and the interrupt) is  
cleared when this register is read.  
BUSY  
The BUSY bit reports whether a previously initiated indirect read or write to the trail trace  
RAM has been completed. BUSY is set high upon writing to the TTB Indirect Address  
Register, and stays high until the access has completed. At this point, BUSY is set low. This  
register should be polled to determine when either new data is available in the TTB Indirect  
Data Register after an indirect read, or when the TTB is ready to accept another write access.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990267, Issue 3  
224  
 复制成功!