S/UNI®-JET Data Sheet  
Released  
Register 343H: E3 TRAN Maintenance and Adaptation Options  
Bit  
Type  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Function  
FERF/RAI  
FEBE  
PTYPE[2]  
PTYPE[1]  
PTYPE[0]  
TUMFRM[1]  
TUMFRM[0]  
TIMEMK  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
0
0
0
0
0
0
0
0
TIMEMK  
The TIMEMK bit determines the state of the Timing Marker bit (bit 8 of the G.832  
Maintenance and Adaptation byte). When TIMEMK is set to logic one, the Timing Marker bit  
in the MA byte is set to logic one. When TIMEMK is set to logic zero, the Timing Marker bit  
in the MA byte is set to logic zero.  
TUMFRM[1:0]  
The TUMFRM[1:0] bits reflect the value to be inserted in the Tributary Unit Multiframe bits  
(bits 6, and 7 of the G.832 Maintenance and Adaptation byte). These bits are logically ORed  
with the TUMFRM[1:0] overhead signals from the TOH input before being inserted in the  
MA byte.  
PTYPE[2:0]  
The PTYPE[2:0] bits reflect the value to be inserted in the Payload Type bits (bits 3,4,5 of the  
G.832 Maintenance and Adaptation byte).  
FEBE  
The FEBE bit reflects the value to be inserted in the FEBE indication bit (bit 2 of the G.832  
Maintenance and Adaptation byte). The FEBE bit value is logically ORed with the FEBE  
indications generated by the FRMR for any detected BIP-8 errors. When the FEBE bit is  
logic one, bit 2 of the G.832 MA byte is set to logic one; when the FEBE bit is logic zero, any  
BIP-8 error indications from the FRMR causes bit 2 of the MA byte to be set to logic one.  