S/UNI®-JET Data Sheet  
Released  
Register 33CH: E3 FRMR Maintenance Event Interrupt Enable  
Bit  
Type  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Function  
FERRE  
PERRE  
AISDE  
FERFE  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
0
0
0
0
0
0
0
0
FEBEE  
PTYPEE  
TIMEMKE  
NATUSEE  
NATUSEE  
The NATUSEE bit is an interrupt enable. When NATUSEE is logic one, an interrupt is  
generated on the INTB output when the National Use bit (bit 12 of the frame in G.751 E3  
mode) changes state. When NATUSEE is logic zero, changes in state of the National Use bit  
does not cause an interrupt on INTB.  
TIMEMKE  
The TIMEMKE bit is an interrupt enable. When TIMEMKE is logic one, an interrupt is  
generated on the INTB output when the Timing Marker bit (bit 8 of the G.832 Maintenance  
and Adaptation byte) changes state after the selected persistency check is applied. When  
TIMEMKE is logic zero, changes in state of the Timing Marker bit does not cause an  
interrupt on INTB.  
PTYPEE  
The PTYPEE bit is an interrupt enable. When PTYPEE is logic one, an interrupt is generated  
on the INTB output when the Payload Type bits (bits 3,4,5 of the G.832 Maintenance and  
Adaptation byte) change state. When PTYPEE is logic zero, changes in state of the Payload  
Type bits does not cause an interrupt on INTB.  
FEBEE  
The FEBEE bit is an interrupt enable. When FEBEE is logic one, an interrupt is generated on  
the INTB output when the FEBE indication bit (bit 2 of the G.832 Maintenance and  
Adaptation byte) changes state. When FEBEE is logic zero, changes in state of the FEBE bit  
does not cause an interrupt on INTB.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990267, Issue 3  