Released  
Register 33AH: E3 FRMR Framing Interrupt Enable  
Bit  
Type  
Function  
Unused  
Unused  
Unused  
CZDE  
LOSE  
LCVE  
COFAE  
OOFE  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
X
X
X
0
0
0
0
0
R/W  
R/W  
R/W  
R/W  
R/W  
OOFE  
The OOFE bit is an interrupt enable. When OOFE is logic one, a change of state of the OOF  
status generates an interrupt and sets the INTB output to logic zero. When OOFE is logic  
zero, changes of state of the OOF status are disabled from causing interrupts on the INTB  
output.  
COFAE  
The COFAE bit is an interrupt enable. When COFAE is logic one, a change of frame  
alignment generates an interrupt and sets the INTB output to logic zero. When COFAE is  
logic zero, changes of frame alignment are disabled from causing interrupts on the INTB  
output.  
LCVE  
The LCVE bit is an interrupt enable. When LCVE is logic one, detection of a LCV generates  
an interrupt and sets the INTB output to logic zero. When LCVE is logic zero, occurrences of  
LCV are disabled from causing interrupts on the INTB output.  
LOSE  
The LOSE bit is an interrupt enable. When LOSE is logic one, a change of state of the loss-  
of-signal generates an interrupt and sets the INTB output to logic zero. When LOSE is logic  
zero, occurrences of loss-of-signal are disabled from causing interrupts on the INTB output.  
CZDE  
The CZDE bit is an interrupt enable. When CZDE is logic one, detection of four consecutive  
zeros in the HDB3-encoded stream generates an interrupt and sets the INTB output to logic  
zero. When CZDE is logic zero, occurrences of consecutive zeros are disabled from causing  
interrupts on the INTB output.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990267, Issue 3  