S/UNI®-JET Data Sheet  
Released  
Register 31EH: PMON FEBE/J2-EXZS Event Count LSB  
Bit  
Type  
R
R
R
R
R
R
R
R
Function  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
FEBE/J2-EXZS[7]  
FEBE/J2-EXZS[6]  
FEBE/J2-EXZS[5]  
FEBE/J2-EXZS[4]  
FEBE/J2-EXZS[3]  
FEBE/J2-EXZS[2]  
FEBE/J2-EXZS[1]  
FEBE/J2-EXZS[0]  
X
X
X
X
X
X
X
X
Register 31FH: PMON FEBE/J2-EXZS Event Count MSB  
Bit  
Type  
Function  
Unused  
Unused  
FEBE/J2-EXZS[13]  
FEBE/J2-EXZS[12]  
FEBE/J2-EXZS[11]  
FEBE/J2-EXZS[10]  
FEBE/J2-EXZS[9]  
FEBE/J2-EXZS[8]  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
X
X
X
X
X
X
X
X
R
R
R
R
R
R
FEBE/J2-EXZS[13:0]  
FEBE/J2-EXZS[13:0] represents the number of DS3 or E3 G.832 FEBEs that have been  
detected since the last time the FEBE error counter was polled.  
In J2 mode, FEBE/J2-EXZS[13:0] represents the number of Excessive Zeros (EXZS is a  
string of eight or more consecutive zeros) that have occurred during the previous  
accumulation interval.  
The counter (and all other counters in the PMON) is polled by writing to any of the PMON  
register addresses (314H to 31FH) or to the S/UNI-JET Identification, Master Reset, and  
Global Monitor Update Register (006H). Such a write transfers the internally accumulated  
count to the FEBE Event Count Registers and simultaneously resets the internal counter to  
begin a new cycle of error accumulation. This transfer and reset is carried out in a manner  
that coincident events are not lost. The transfer takes 255 RCLK cycles to complete in DS3  
mode and three RCLK cycles to complete in E3 and J2 mode.  