S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet
Preliminary
Register 0x187: Performance Management RAM Row 7 Word 1 .................................283
Register 0x188: Performance Management RAM Row 7 Word 2 (MSW) .....................283
Register 0x189: Performance Management Threshold A ..............................................284
Register 0x18A: Performance Management Threshold B..............................................285
Register 0x18B: Performance Management Threshold C .............................................285
Register 0x18C: Performance Management Threshold D .............................................285
Register 0x190: VC Table Change of Connection State FIFO Status ............................286
Register 0x191: VC Table Change of Connection State FIFO Data...............................287
Register 0x198: Count Rollover FIFO Status.................................................................288
Register 0x199: Count Rollover FIFO Data....................................................................289
Register 0x1A0: Per-PHY Counter Configuration ..........................................................291
Register 0x1A1: Per-PHY Counter Control ....................................................................293
Register 0x1A8: Per-PHY CLP0 Cell Count Holding Register.......................................296
Register 0x1A9: Per PHY CLP1 Cell Count Holding Register .......................................298
Register 0x1AA: Per PHY Valid RM Cell Counts Holding Register................................299
Register 0x1AB: Per PHY Valid OAM Cell Counts Holding Register.............................300
Register 0x1AC: Per PHY Errored OAM/RM Cell Counts Holding Register..................301
Register 0x1AD: Per PHY Invalid VPI/VCI/PTI Cell Counts Holding Register...............302
Register 0x1AE: Per-PHY EFCI/Non-Zero GFC Cell Count Holding Register ..............303
Register 0x1AF: Per-PHY Timed-Out Cell Count Holding Register...............................304
Register 0x1B0: Per PHY Last Unknown VPI & VCI Holding Register..........................305
Register 0x1C0: Reserved .............................................................................................307
Register 0x200: RxL Configuration.................................................................................308
Register 0x201: RxL Interrupt Enable ............................................................................310
Register 0x202: RxL Interrupt.........................................................................................311
Register 0x208: RxL PHY Indirect Address....................................................................312
Register 0x209: RxL PHY Indirect Data .........................................................................313
Register 0x20A: RxL Calendar Length...........................................................................314
Register 0x20B: RxL Calendar Indirect Address and Data ............................................315
Register 0x20C: RxL Data Type Field ............................................................................317
Register 0x220: TxP Configuration.................................................................................318
Register 0x221: TxP Interrupt.........................................................................................320
Register 0x222: TxP Interrupt Enable ............................................................................321
Register 0x223: TxP Data Type Field.............................................................................322
Register 0x240: Input SDQ Control................................................................................323
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990553, Issue 4
148