S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Figure 18 Termination of F4 End-to-End Point Connection  
Connection End-Point (End-to-End Point)  
Segment End-Point  
VCC-AIS-Ete (Connection within a defined segment)  
VCC1  
VCC2  
VCC-AIS-Seg (Connection within a defined segment)  
VCC-AIS-EtE (Connection not within a defined segment)  
VCC3  
VCC-AIS-EtE  
VCC-RDI-Seg  
F4 (VPC)  
VCC-RDI-EtE  
VCC4  
VCC5  
VCC-RDI-Seg  
VCC-RDI-EtE  
VPC-AIS-EtE  
VPC-RDI-EtE  
Figure 18 above illustrates the scenario where a VPC is being terminated at an end-to-end point at  
the S/UNI-ATLAS-3200. In this scenario, the VPC connection is configured as an end-to-end  
point and has its VPC Pointer Active bit set to logic 0. If an end-to-end VPC-AIS cell is received,  
it is terminated and an end-to-end VPC RDI cell is generated within 0.5 seconds (assuming the  
AUTO_RDI bit is logic 1 in the VC Table). The response of the switched VCCs is as follows:  
VCC1 is belongs to a segment flow, therefore both segment and ETE VCC-AIS cells are  
generated within 0.5 seconds of noticing that the VPC connection is in AIS alarm, and once per  
second (nominally) thereafter until the VPC connection exits the AIS alarm state.  
VCC2 belongs to an end-to-end flow, therefore an end-to-end VCC-AIS cell is generated within  
0.5 seconds of noticing that the VPC connection is in AIS alarm, and once per second (nominally)  
thereafter until the VPC connection exits the AIS alarm state.  
VCC3 is a segment end-point, therefore a segment VCC-RDI cell and an end-to-end VCC-AIS  
cell are generated within 0.5 seconds of noticing that the VPC connection is in AIS alarm  
(assuming the AUTO_RDI bit is logic 1 in the VC Table), and once per second (nominally)  
thereafter until the VPC connection exits the AIS alarm state.  
VCC4 is an end-to-end point, therefore an end-to-end VCC-RDI cell is generated within 0.5  
seconds of noticing that the VPC connection is in AIS alarm (assuming the AUTO_RDI bit is  
logic 1 in the VC Table), and once per second (nominally) thereafter until the VPC connection  
exits the AIS alarm state.  
VCC5 is a segment end-point and an end-to-end point, therefore, a segment VCC-RDI and an  
end-to-end VCC-RDI cell are generated within 0.5 seconds of noticing that the VPC connection is  
in AIS (assuming the AUTO_RDI bit is logic 1 in the VC Table), and once per second  
(nominally) thereafter until the VPC connection exits the AIS alarm state.  