欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7325-TC 参数 Datasheet PDF下载

PM7325-TC图片预览
型号: PM7325-TC
PDF下载: 下载PDF文件 查看货源
内容描述: S / UNI - ATLAS -3200电信标准产品数据表初步 [S/UNI-ATLAS-3200 Telecom Standard Product Data Sheet Preliminary]
分类和应用: ATM集成电路SONET集成电路SDH集成电路电信电路异步传输模式
文件页数/大小: 432 页 / 2222 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7325-TC的Datasheet PDF文件第99页浏览型号PM7325-TC的Datasheet PDF文件第100页浏览型号PM7325-TC的Datasheet PDF文件第101页浏览型号PM7325-TC的Datasheet PDF文件第102页浏览型号PM7325-TC的Datasheet PDF文件第104页浏览型号PM7325-TC的Datasheet PDF文件第105页浏览型号PM7325-TC的Datasheet PDF文件第106页浏览型号PM7325-TC的Datasheet PDF文件第107页  
S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Name  
Description  
an SDUTYP equal to logic 1). The MFL conformance test can be  
disabled by setting the MFL field in the VC table to all ones. This field  
should be initialized to MFL – 1.  
GFR State[2:0]  
The GFR State is an internally maintained state variable which must be  
programmed to 0 at connection startup and not changed thereafter.  
10.8 Cell Counting  
The S/UNI-ATLAS-3200 maintains counts on a per-connection basis, per-PHY basis and over the  
aggregate cell stream.  
The following parameters are stored on a per-connection basis in the VC Tables:  
Two 32-bit “billing” cell counts that may be programmed to count any combination of the  
following:  
A. CLP0 user cells.  
B. CLP1 user cells.  
C. CLP0 OAM cells.  
D. CLP1 OAM cells.  
E. CLP0 RM cells.  
F. CLP1 RM cells.  
G. CLP0 cells with Invalid VCI/PTI  
H. CLP1 cells with Invalid VCI/PTI.  
Three Non-compliant cell counts, which may count (Non-Compliant CLP0 or CLP0+1 cells,  
Discarded CLP0 or CLP0+1 Cells, Tagged Cells, Total CLP 0 or CLP0+1 frames, Non-  
Compliant CLP0 or CLP1 Frames, etc.) These counts are described in Section 10.7, which  
covers policing.  
Per-PHY counts of CLP0, CLP1, valid OAM, valid RM, Invalid OAM/RM, Congested (EFCI  
or GFC), timed-out, and Bad VPI/VCI/PTI cells.  
The two programmable 32-bit cell counts represent the state of the cells before policing. The  
non-compliant cell counts can be used to derive the cell counts after policing.  
The programmability of the two 32-bit cell counts allows the ability to provision scheduled  
measurements and special studies on each connection.  
When aggregating or terminating a VPC, the VPC OAM Connection’s 32-bit billing counts are  
updated based on the total traffic arriving on the VPC. That is, all cells arriving on associated  
VCCs are counted as user cells in the VPC OAM Connection. This permits aggregate counts to  
be generated with little microprocessor effort.  
If Performance Management is activated, a range of forward monitoring and backward reporting  
statistics are stored. These statistics are described in Section 10.14 which covers Performance  
Management.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
103  