欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7325-TC 参数 Datasheet PDF下载

PM7325-TC图片预览
型号: PM7325-TC
PDF下载: 下载PDF文件 查看货源
内容描述: S / UNI - ATLAS -3200电信标准产品数据表初步 [S/UNI-ATLAS-3200 Telecom Standard Product Data Sheet Preliminary]
分类和应用: ATM集成电路SONET集成电路SDH集成电路电信电路异步传输模式
文件页数/大小: 432 页 / 2222 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7325-TC的Datasheet PDF文件第97页浏览型号PM7325-TC的Datasheet PDF文件第98页浏览型号PM7325-TC的Datasheet PDF文件第99页浏览型号PM7325-TC的Datasheet PDF文件第100页浏览型号PM7325-TC的Datasheet PDF文件第102页浏览型号PM7325-TC的Datasheet PDF文件第103页浏览型号PM7325-TC的Datasheet PDF文件第104页浏览型号PM7325-TC的Datasheet PDF文件第105页  
S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Table 27 Per-PHY and per-VC Non-Compliant Cell Counting PHYVCCount=1  
PHYVCCount=1  
Per-VC Policing  
Compliant  
Non-Compliant  
Per-PHY Policing  
Compliant  
No update.  
Update per-VC non-compliant  
counts  
Update per-PHY non-  
compliant counts.  
Non-Compliant  
Update per-VC non-compliant Update per-VC non-compliant  
counts.  
counts.  
Update per-PHY non-  
Update per-PHY non-  
compliant counts  
compliant counts.  
10.7.3 Guaranteed Frame Rate Policing  
The S/UNI-ATLAS-3200 supports Guaranteed Frame Rate (GFR) policing in accordance with the  
ATM Forum Traffic Management Specification 4.1. A total of four policing actions are observed  
for GFR policing. They are: Maximum Frame Length (MFL) conformance test, Peak Cell Rate  
(PCR) test, Minimum Cell Rate (MCR) conformance test, and the CLP Conformance test. When  
GFR policing is enabled, the GFR policing algorithm is enabled. The conformance tests are  
evaluated sequentially, in the following order:  
1. MFL conformance test. When an End Of Message cell in a packet is received, the Remaining  
Frame Count field of the VC Table is loaded, after testing for MFL conformance with the  
current value, with the value programmed in the Maximum Frame Length field in the VC  
Table. The Remaining Frame Count is then decremented with each cell received in the new  
frame. If this value reaches zero before an End Of Message cell is received, the remainder of  
the frame is discarded (the EOM cell is identified by having an SDUTYP equal to logic 1).  
The MFL conformance test can be disabled by setting the MFL field in the VC table to all  
ones.  
2. PCR conformance test. This test is performed using GCRA1 in much the same manner as  
normal cell policing. However, for compliance to the GFR specification, Action 1 must be  
set to 11 (discard). If the PCR conformance test is deemed to be non-compliant, the  
remainder of the cells in the current frame will be discarded. If the non-compliant cell is the  
start of packet, then a complete packet discard is executed; if it is in the middle of a packet, a  
partial packet discard is executed; if it is the end of a packet, it is discarded along with every  
subsequent cell until a EOP is received which is not discarded.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
101  
 复制成功!