欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7325-TC 参数 Datasheet PDF下载

PM7325-TC图片预览
型号: PM7325-TC
PDF下载: 下载PDF文件 查看货源
内容描述: S / UNI - ATLAS -3200电信标准产品数据表初步 [S/UNI-ATLAS-3200 Telecom Standard Product Data Sheet Preliminary]
分类和应用: ATM集成电路SONET集成电路SDH集成电路电信电路异步传输模式
文件页数/大小: 432 页 / 2222 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7325-TC的Datasheet PDF文件第102页浏览型号PM7325-TC的Datasheet PDF文件第103页浏览型号PM7325-TC的Datasheet PDF文件第104页浏览型号PM7325-TC的Datasheet PDF文件第105页浏览型号PM7325-TC的Datasheet PDF文件第107页浏览型号PM7325-TC的Datasheet PDF文件第108页浏览型号PM7325-TC的Datasheet PDF文件第109页浏览型号PM7325-TC的Datasheet PDF文件第110页  
S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
If the CC_Activate_Segment bit is a logic 1, and no user cells have been transmitted within a 1.0  
second (nominal) window, a segment CC cell is generated and sent to the Output Cell Interface.  
The forced generation of CC cells (independent of the flow of user cells) at one second (nominal)  
intervals is enabled when the CC_Activate_Segment bit is logic 1 and the ForceCC register bit is  
logic 1. If the ForceCC register bit is logic 0, then the generation of CC cells is dependent on the  
flow of user cells. Regardless of the state of the CC_Activate_Segment bit, if no user cells or  
segment CC cells have been received within a 3.5 +/- 0.5 sec window, the CC_Alarm_Segment  
status bit is set. If the connection FM_Interrupt_Enable bit is set, a globally maskable interrupt  
will be asserted at the change of state of the segment CC alarm. The Segment CC alarm is cleared  
upon the reception of the first user or Segment CC cell.  
If the S/UNI-ATLAS-3200 is configured as a segment end-point, and the AUTO_RDI and  
CC_AIS_RDI bits of the OAM Configuration field is set, a segment RDI cell is generated once  
per second into the reverse direction while the segment CC alarm is declared. In addition, if the  
AUTO_AIS bit is logic 1, then an ETE AIS cell is generated once per second while segment CC  
alarm is declared.  
If the S/UNI-ATLAS-3200 is not configured as a segment end point, then if the Segment_Flow  
bit is logic 1, the AUTO_AIS register bit is set, and the CC_AIS_RDI bit is set in the OAM  
Configuration field of the VC table, a segment AIS cell is generated once per second while  
Segment CC alarm is declared and Segment AIS alarm is not declared.  
When AIS cells are generated by the S/UNI-ATLAS-3200 due to the AUTO_AIS function, the  
per-PHY AIS generation bits, or the per-VC Send_AIS bits, the Generated_Defect_Type[7:0]  
field in the VC table is used for the defect type, and the Defect Location register fields are used  
for the defect location.  
When F5 AIS cells are generated due to F4 AIS, the defect location and type of the F4 AIS cell  
that caused the alarm are sent. Similarly, when F4 Ete AIS cells are sent as a result of reception  
of Segment AIS cells (via the APSx function) the Defect Location and Type of the received  
Segment AIS cell is used.  
For each segment OAM capability described above, the same capability exists for the End-to-  
End.  
The S/UNI-ATLAS-3200 also supports the generation of F5 AIS and RDI cells when associated  
F4 connections, which are terminated, enter the AIS alarm state. This is described in detail in  
section 10.10.  
The S/UNI-ATLAS-3200 may be configured on a per-PHY basis to output AIS or RDI cells (or  
both) on all connections whose PHYID matches those set in a programmable register. The Per-  
PHY RDI Cell Generation Control and Per-PHY AIS Cell Generation Control registers control  
the generation of RDI and AIS cells on entire PHYs at once. When the PHY AIS bits are set, end-  
to-end cells (and, if Segment_Flow is logic 1, segment AIS cells) are sent once per second, except  
at flow end points. When the PHY RDI bits are set, RDI cells will be sent once per second in the  
reverse flow direction on all connections which are segment or end-to-end points. In the case of a  
segment end point, one segment RDI and one end-to-end AIS cell will be sent per second, if both  
the PHY AIS and PHY RDI bits are set.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
106  
 复制成功!