欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7325-TC 参数 Datasheet PDF下载

PM7325-TC图片预览
型号: PM7325-TC
PDF下载: 下载PDF文件 查看货源
内容描述: S / UNI - ATLAS -3200电信标准产品数据表初步 [S/UNI-ATLAS-3200 Telecom Standard Product Data Sheet Preliminary]
分类和应用: ATM集成电路SONET集成电路SDH集成电路电信电路异步传输模式
文件页数/大小: 432 页 / 2222 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7325-TC的Datasheet PDF文件第100页浏览型号PM7325-TC的Datasheet PDF文件第101页浏览型号PM7325-TC的Datasheet PDF文件第102页浏览型号PM7325-TC的Datasheet PDF文件第103页浏览型号PM7325-TC的Datasheet PDF文件第105页浏览型号PM7325-TC的Datasheet PDF文件第106页浏览型号PM7325-TC的Datasheet PDF文件第107页浏览型号PM7325-TC的Datasheet PDF文件第108页  
S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
The S/UNI-ATLAS-3200 can be configured to have some of its counters roll over or saturate at  
all ones. All per-PHY counts, the per-connection cell counts, non-compliant cell counts, and the  
PM counts are configurable in this manner.  
The Rollover_FIFO_EN bit in the Configuration field of the VC table controls whether the 32-bit  
per-VC Cell counts saturate, or whether they generate Count Rollover FIFO entries when their  
MSB is logic 1, and then reset their MSBs to 0. The Policing Rollover FIFO EN bit in the  
Policing Configuration field performs this function for the non-compliant counts; The PHY  
Policing Rollover_FIFO_EN bit in the PHY Policing RAM performs the same function for the  
per-PHY non-compliant counts, as does the PHY Rollover_FIFO_EN bit in the Per-PHY Counter  
Configuration register for the other per-PHY counts. The PM_Rollover_FIFO_EN bit in the PM  
Configuration Field of the Internal PM table controls whether the Performance Management  
counts generate Count Rollover FIFO entries. The Count Rollover FIFO is described in Section  
10.16.  
All per-PHY and per-VC counts have a Clear On Read option. If this bit is logic 1, then when the  
microprocessor reads the counter value, the value is immediately set to zero. If the per-PHY or  
per-VC Clear On Read register bit is logic 0, the counter value is not cleared when it is read, and  
the value must be cleared by explicitly writing all zeros to that counter location.  
In order to allow for a time-of-day billing mechanism, the S/UNI-ATLAS-3200 provides  
Alternate Count fields for the general 32-bit counts. When the Alternate_Count bit in the Cell  
Processor Configuration register is set to logic 1, the 32-bit cell counts in all VCs stop  
incrementing, and the Alternate Counts are incremented instead. The cell counts may then be  
read at leisure by the microprocessor. When the Alternate_Count bit is set to logic 0 again, the  
counting reverts to the regular 32-bit counts, and the Alternate Counts may be read (and  
presumably cleared) at leisure by the microprocessor.  
One of the objectives of counting is to count, somewhere, every cell that arrives. Almost all cells  
can be counted in the per-VC cell counts. However, cells that do not belong to any particular  
connection (i.e. they do not search to a valid, active connection) cannot be counted per-VC.  
These cells have their own per-PHY count, the Invalid VPI/VCI/PTI cell count. The only overlap  
between this count and the per-VC counts is for cells with a reserved VCI or PTI. The  
Cnt_Rsvd_VCI_PTI bit in the per-PHY count configuration register controls whether cells with  
reserved VCI or PTI are counted in the Invalid VPI/VCI/PTI cell count.  
10.9 Operations, Administration and Maintenance (OAM) Cell  
Servicing  
The S/UNI-ATLAS-3200 is capable of terminating and monitoring F4 and F5 segment and end-  
to-end OAM flows. Complete processing of Fault Management cells is provided on all  
connections. Performance Management is provided on a limited number of connections (512  
simultaneous sessions in each direction are supported). Activate/Deactivate and Undefined OAM  
cells are passed to the Microprocessor Cell Interface or to the Output Cell Interface for external  
processing. Loopback cells are examined, and routed based on their Loopback Indication,  
Loopback Location ID, and Source ID.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
104  
 复制成功!