PM6341 E1XC  
DATA SHEET  
PMC-910419  
ISSUE 8  
E1 FRAMER/TRANSCEIVER  
Figure 26  
- XFDL Underrun Sequence  
Serial Data  
inserted into  
ESF FDL  
Flag D1  
D2  
D3 Abort Flag D1  
D2  
TDLINT  
TDLUDR  
D[7:0]  
INTE D1 D2  
D3  
UDR  
INTE  
INTE D1 D2  
D3  
D4  
This diagram shows the relationship between XFDL inputs and outputs in the  
case of an underrun error. An underrun error occurs if the XFDL finishes  
transmitting the current message byte before the processor writes the next byte  
into the XFDL Transmit Data Register; that is, the processor fails to write data to  
the XFDL in time. In this example, data is not written to the XFDL within the  
time-out period after TDLINT goes high at the beginning of the transmission of  
byte D3. The TDLUDR interrupt becomes active at this point, and an abort,  
followed by a flag, is sent out on the data link. Meanwhile, the processor must  
clear the TDLUDR interrupt by setting the UDR bit in the XFDL Interrupt Status  
Register to logic 0. The TDLINT interrupt should also be disabled at this time by  
setting the INTE bit in the XFDL Configuration Register to logic 0. The data  
frame can then be restarted as usual, by setting the INTE bit logic to 1.  
Transmission of the frame then proceeds normally.  
14.4 Using the Loopback Modes  
The E1XC provides four loopback modes to aid in network and system  
diagnostics.The network loopbacks (PAYLOAD and LINE) can be initiated at any  
time via the µP interface, but are usually initiated once an inband loopback  
activate code is detected.The system loopbacks (Diagnostic DIGITAL and  
METALLIC) can be initiated at any time by the system via the µP interface to  
check the path of system data through the transceiver.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  