STANDARD PRODUCT
PM5365 TEMAP
DATASHEET
PMC-1991148
ISSUE 3
HIGH DENSITY VT/TU MAPPER
AND M13 MULTIPLEXER
standard pins, TRSTB, TCK, TMS, TDI and TDO used to control the TAP
controller and the boundary scan registers. The TRSTB input is the active-low
reset signal used to reset the TAP controller. TCK is the test clock used to
sample data on input, TDI and to output data on output, TDO. The TMS input is
used to direct the TAP controller through its states. The basic boundary scan
architecture is shown below.
Figure 31: Boundary Scan Architecture
Boundary Scan
TDI
Register
Device Identification
Register
Bypass
Register
Instruction
Register
and
Mux
DFF
TDO
Decode
Control
TMS
Test
Access
Port
Select
Tri-state Enable
Controller
TRSTB
TCK
The boundary scan architecture consists of a TAP controller, an instruction
register with instruction decode, a bypass register, a device identification register
and a boundary scan register. The TAP controller interprets the TMS input and
generates control signals to load the instruction and data registers. The
instruction register with instruction decode block is used to select the test to be
executed and/or the register to be accessed. The bypass register offers a single-
Proprietary and Confidential to PMC-Sierra, Inc. and for its Customers’ Internal Use
180