STANDARD PRODUCT  
PM5365 TEMAP  
DATASHEET  
PMC-1991148  
ISSUE 3  
HIGH DENSITY VT/TU MAPPER  
AND M13 MULTIPLEXER  
The pattern generator consists of a 32 bit shift register and a single XOR gate.  
The XOR gate output is fed into the first stage of the shift register. The XOR  
gate inputs are determined by values written to the length register (PL[4:0]) and  
the tap register (PT[4:0], when the PS bit is low). When PS is high, the pattern  
detector functions as a recirculating shift register, with length determined by  
PL[4:0].  
Generating and detecting repetitive patterns  
When a repetitive pattern (such as 1-in-8) is to be generated or detected, the PS  
bit must be set to logic 1. The pattern length register must be set to (N-1), where  
N is the length of the desired repetitive pattern. Several examples of  
programming for common repetitive sequences are given below in the Common  
Test Patterns section.  
For pattern generation, the desired pattern must be written into the PRGD  
Pattern Insertion registers. The repetitive pattern will then be continuously  
generated. The generated pattern will be inserted in the output data stream, but  
the phase of the pattern cannot be guaranteed.  
For pattern detection, the PRGD will determine if a repetitive pattern of the length  
specified in the pattern length register exists in the input stream. It does so by  
loading the first N bits from the data stream, and then monitoring to see if the  
pattern loaded repeats itself error free for the subsequent 48 bit periods. It will  
repeat this process until it finds a repetitive pattern of length N, at which point it  
begins counting errors (and possibly re-synchronizing) in the same way as for  
pseudo-random sequences. Note that the PRGD does NOT look for the pattern  
loaded into the Pattern Insertion registers, but rather automatically detects any  
repetitive pattern of the specified length. The precise pattern detected can be  
determined by initiating a PRGD update, setting PDR[1:0] = 00 in the PRGD  
Control register, and reading the Pattern Detector registers (which will then  
contain the 32 bits detected immediately prior to the strobe).  
Common Test Patterns  
The PRGD can be configured to monitor the standardized pseudo random and  
repetitive patterns described in ITU-T O.151. The register configurations  
required to generate these patterns and others are indicated in Table 30 and  
Table 31 below:  