STANDARD PRODUCT  
PM5365 TEMAP  
DATASHEET  
PMC-1991148  
ISSUE 3  
HIGH DENSITY VT/TU MAPPER  
AND M13 MULTIPLEXER  
Update-IR  
The update instruction register state is used to load a new instruction into the  
instruction register. The new instruction must be scanned in using the Shift-IR  
state. The load occurs on the falling edge of TCK.  
The Pause-DR and Pause-IR states are provided to allow shifting through the  
test data and/or instruction registers to be momentarily paused.  
Boundary Scan Instructions  
The following is a description of the standard instructions. Each instruction  
selects a serial test data register path between input, TDI and output, TDO.  
BYPASS  
The bypass instruction shifts data from input, TDI to output, TDO with one TCK  
clock period delay. The instruction is used to bypass the device.  
EXTEST  
The external test instruction allows testing of the interconnection to other  
devices. When the current instruction is the EXTEST instruction, the boundary  
scan register is placed between input, TDI and output, TDO. Primary device  
inputs can be sampled by loading the boundary scan register using the  
Capture-DR state. The sampled values can then be viewed by shifting the  
boundary scan register using the Shift-DR state. Primary device outputs can be  
controlled by loading patterns shifted in through input TDI into the boundary scan  
register using the Update-DR state.  
SAMPLE  
The sample instruction samples all the device inputs and outputs. For this  
instruction, the boundary scan register is placed between TDI and TDO.  
Primary device inputs and outputs can be sampled by loading the boundary scan  
register using the Capture-DR state. The sampled values can then be viewed by  
shifting the boundary scan register using the Shift-DR state.  
IDCODE  
The identification instruction is used to connect the identification register  
between TDI and TDO. The device's identification code can then be shifted out  
using the Shift-DR state.  