STANDARD PRODUCT  
PM4351 COMET  
DATA SHEET  
PMC-1970624  
ISSUE 10  
COMBINED E1/T1 TRANSCEIVER  
Table 15  
- E1-FRMR Framing States  
State  
Out of Frame Out of Offline Frame  
FAS_Find_1  
Yes  
Yes  
Yes  
No  
No  
No  
NFAS_Find  
FAS_Find_2  
No  
BFA  
No  
CRC to CRC Interworking  
FAS_Find_1_Par  
NFAS_Find_Par  
FAS_Find_2_Par  
BFA_Par  
No  
No  
No  
Yes  
Yes  
Yes  
No  
No  
No  
No  
CRC to non-CRC Interworking  
No  
No  
The states of the primary basic framer and the parallel/offline framer in the  
E1-FRMR block at each stage of the CRC multiframe alignment algorithm are  
shown in Table 15.  
From an out of frame state, the E1-FRMR attempts to find basic frame alignment  
in accordance with the FAS/NFAS/FAS G.706 Basic Frame Alignment procedure  
outlined above. Upon achieving basic frame alignment, a 400 ms timer is  
started, as well as an 8 ms timer. If two CRC multiframe alignment signals  
separated by a multiple of 2 ms are observed before the 8 ms timer has expired,  
CRC multiframe alignment is declared.  
If the 8 ms timer expires without achieving multiframe alignment, a new offline  
search for basic frame alignment is initiated. This search is performed in  
accordance with the Basic Frame Alignment procedure outlined above.  
However, this search does not immediately change the actual basic frame  
alignment of the system (i.e., PCM data continues to be processed in  
accordance with the first basic frame alignment found after an out of frame state  
while this frame alignment search occurs as a parallel operation).  
When a new basic frame alignment is found by this offline search, the 8 ms timer  
is restarted. If two CRC multiframe alignment signals separated by a multiple of  
2 ms are observed before the 8 ms timer has expired, CRC multiframe alignment  
PROPRIETARY AND CONFIDENTIAL  