STANDARD PRODUCT  
PM4351 COMET  
DATA SHEET  
PMC-1970624  
ISSUE 10  
COMBINED E1/T1 TRANSCEIVER  
searches are done in the next bit position, modulo 512. This facilitates the  
discovery of the correct frame alignment, even in the presence of fixed timeslot  
data imitating the FAS.  
These algorithms provide robust framing operation even in the presence of  
random bit errors: framing with algorithm #1 or #2 provides a 99.98% probability  
-3  
of finding frame alignment within 1 ms in the presence of 10 bit error rate and  
no mimic patterns.  
Once frame alignment is found, the block sets the OOF indication low, indicates  
a change of frame alignment (if it occurred), and monitors the frame alignment  
signal, indicating errors occurring in the 7-bit FAS pattern and in bit 2 of NFAS  
frames, and indicating the debounced value of the Remote Alarm bit (bit 3 of  
NFAS frames). Using debounce, the Remote Alarm bit has <0.00001%  
-3  
probability of being falsely indicated in the presence of a 10 bit error rate. The  
block declares loss of frame alignment if 3 consecutive FASs have been received  
in error or, additionally, if bit 2 of NFAS frames has been in error for 3  
-3  
consecutive occasions. In the presence of a random 10 bit error rate the frame  
loss criteria provides a mean time to falsely lose frame alignment of >12 minutes.  
The E1-FRMR can be forced to initiate a basic frame search at any time when  
any of the following conditions are met:  
the software re-frame bit in the E1-FRMR Frame Alignment Options register  
goes to logic 1;  
the CRC Frame Find Block is unable to find CRC multiframe alignment; or  
the CRC Frame Find Block accumulates excessive CRC evaluation errors  
(915 CRC errors in 1 second) and is enabled to force a re-frame under that  
condition.  
CRC Multiframe Alignment Procedure  
The E1-FRMR searches for CRC multiframe alignment by observing whether the  
International bits (bit 1 of TS 0) of NFAS frames follow the CRC multiframe  
alignment pattern. Multiframe alignment is declared if at least two valid CRC  
multiframe alignment signals are observed within 8 ms, with the time separating  
two alignment signals being a multiple of 2 ms  
Once CRC multiframe alignment is found, the OOCMFV register bit is set to  
logic 0, and the E1-FRMR monitors the multiframe alignment signal, indicating  
errors occurring in the 6-bit MFAS pattern, errors occurring in the received CRC  
and the value of the FEBE bits (bit 1 of frames 13 and 15 of the multiframe).  
The E1-FRMR declares loss of CRC multiframe alignment if basic frame  