PM4341AT1XC  
DATA SHEET  
PMC-900602  
ISSUE 7  
T1 FRAMER/TRANSCEIVER  
indicating the next data byte is the first channel of the frame, or the first channel  
of the first frame of the superframe.  
8.17 BasicTransmitter (XBAS)  
The Basic Transmitter function is provided by an XBAS.  
The BASIC TRANSMITTER (XBAS) block generates the 1.544 Mbit/s T1 data  
stream according to SF, ESF, T1DM, or SLC®96 formats.  
A serial PCM control stream provides per channel control of idle code  
substitution, data inversion (either all 8 bits, sign bit only, or magnitude only),  
digital milliwatt substitution, and zero code suppression. Three types of zero code  
suppression (GTE, Bell and DDS) are supported and selected on a per channel  
basis to provide minimum ones density control. A serial signalling control stream  
provides per channel control of robbed bit signalling and selection of the  
signalling source. All channels can be forced into a trunk conditioning state (idle  
code substitution and signalling conditioning) by use of the Master Trunk  
Conditioning bit in the Configuration Register.  
A data link is provided for ESF, T1DM and SLC®96 modes. Serial data input and  
clock output allow a variety of data link sources including bit oriented codes and  
LAPD messages. Support is provided for the transmission of framed or unframed  
Inband Code sequences and transmission of AIS or Yellow alarm signals for all  
formats.  
PCM output signals may be selected to conform to B8ZS or AMI line coding.  
The transmitter can be disabled for framing via the disable bit in the Transmit  
Functions Enable register. When transmitting ESF formatted data, the framing bit,  
datalink bit, or the CRC-6 bit from the input PCM stream can be by-passed to  
the output PCM stream. Finally, the transmitter can be by-passed completely to  
provide BPV transparency.  
8.18 Transmit Per-Channel Serial Controller (TPSC)  
The Transmit Per-channel Serial Controller allows data and signalling trunk  
conditioning or idle code to be applied on the transmit DS-1 stream on a per-  
channel basis. It also allows per-channel control of zero code suppression, data  
inversion, and application of digital milliwatt.  
The Transmit Per-channel Serial Controller function is provided by a PER-  
CHANNEL SERIAL CONTROLLER (PCSC) block. The PCSC is a general  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
47  