PM4341AT1XC  
DATA SHEET  
PMC-900602  
ISSUE 7  
T1 FRAMER/TRANSCEIVER  
Pin  
Pin No.  
Name  
Type  
PQFP PLCC Function  
VDDI[0]  
VDDI[1]  
Power 11  
49  
19  
51  
Core power pins (VDDI[1:0]).These pins  
must be connected to a common, well  
decoupled +5 VDC supply together with  
the VDDO[2:0] pins.  
VSSO[0]  
VSSO[1]  
VSSO[2]  
VSSO[3]  
Ground 70  
1
Pad ring ground pins (VSSO[3:0]).These  
pins must be connected to a common  
ground together with the VSSI[1:0] pins.  
Care must be taken to avoid coupling  
noise induced on the VSSO pins into the  
VSSI pins.  
9
17  
43  
60  
38  
58  
VSSI[0]  
VSSI[1]  
Ground 10  
50  
18  
52  
Core ground pins (VSSI[1:0]).These pins  
must be connected to a common ground  
together with the VSSO[2:0] pins.  
Notes on Pin Description:  
1. VDDI and VSSI are the +5 V and ground connections, respectively, for the  
core circuitry of the device. VDDO and VSSO are the +5 V and ground  
connections, respectively, for the pad ring circuitry of the device. TAVD and  
TAVS are the +5V and ground connections, respectively, for the transmit  
analog circuitry of the device. These power supply connections must all be  
utilized and must all connect to a common +5 V or ground rail, as appropriate.  
There is no low impedance connection within the PM4341A between the  
core, pad ring, and transmit analog supply rails. Failure to properly make  
these connections may result in improper operation or damage to the device.  
Care must be taken to avoid coupling of noise into the transmit analog supply  
rails.  
2. RAVD and RAVS are the +5 V and ground connections, respectively, for the  
receive analog circuitry of the device. These power supply connections need  
only be used if the receive analog function is desired and should then  
connect to a common +5 V or ground rail, as appropriate, with the core, pad  
ring, and transmit analog supply rails. There is no low impedance connection  
within the PM4341A between the receive analog supply rail and other supply  
rails. When the receive analog function is not desired, RAVD should be  
connected to RAVS. Care must be taken to avoid coupling of noise into the  
receive analog supply rails.  