T1 FRAMER/TRANSCEIVER  
Register 2FH: ALMI Alarm Detection Status  
Bit  
Type  
Function  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Unused  
Unused  
Unused  
Unused  
Unused  
REDD  
X
X
X
X
X
X
X
X
R
R
R
YELD  
AISD  
This register indicates the presence or absence of one or more OOF  
occurrences within the last 40ms; the presence or absence of the YELLOW  
ALARM signal over the last 40ms; and indicates the presence or absence of the  
AIS ALARM signal over the last 60ms.  
REDD:  
When REDD is a logic 1, one or more out of frame events have occurred  
during the last 40ms interval. When REDD is a logic 0, no out of frame events  
have occurred within the last 40ms interval.  
YELD:  
When YELD is logic 1, a valid YELLOW signal was present during the last  
40ms interval. When YELD is logic 0, the YELLOW signal was absent during  
the last 40ms interval. For each framing format, a valid YELLOW signal is  
deemed to be present if:  
bit 2 of each channel is not logic 0 for 16 or fewer times during the  
40 ms interval for SF and SLC®96 framing formats;  
the Y-bit is not logic 0 for 4 or fewer times during the 40 ms interval  
for T1DM framing format;  
the 16-bit YELLOW bit oriented code is received error-free 8 or  
more times during the interval for ESF framing format with a 4 kHz  
data link;  
the 16-bit YELLOW bit oriented code is received error-free 4 or  
more times during the interval for ESF framing format with a 2 kHz  
data link.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  