PM4341AT1XC
DATA SHEET
PMC-900602
ISSUE 7
T1 FRAMER/TRANSCEIVER
Register 2EH: ALMI Interrupt Status
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Unused
Unused
YELI
REDI
AISI
X
X
X
X
X
X
X
X
R
R
R
R
R
R
YEL
RED
AIS
This register indicates which of the three CFA's generated an interrupt when their
logic state changed in bit positions 5 through 3; and indicates the current state of
each CFA in bit positions 2 through 0. A logic 1 in the status positions (YELI,
REDI, AISI) indicate that a state change in the corresponding CFA has
generated an interrupt; a logic 0 in the status positions indicates that no state
change has occurred. Both the status bit positions (bits 5 through 3) and the
interrupt generated because of the change in CFA state are cleared to logic 0
when this register is read.