PM4341AT1XC  
DATA SHEET  
PMC-900602  
ISSUE 7  
T1 FRAMER/TRANSCEIVER  
Register 2CH: ALMI Configuration  
Bit  
Type  
Function  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Unused  
Unused  
Unused  
ESF  
X
X
X
0
R/W  
R/W  
R/W  
FMS1  
0
FMS0  
0
Unused  
Unused  
X
X
This register allows selection of the framing format and the data rate of the  
Facility Data Link in ESF to allow operation of the CFA detection algorithms.  
ESF:  
The ESF bit selects either extended superframe format or enables the frame  
mode select bits to select either regular superframe, T1DM, "alternate" T1DM,  
or SLC®96 framing formats. A logic 1 in the ESF bit position selects ESF; a  
logic 0 bit enables FMS1 and FMS0 to select SF, T1DM, "alternate" T1DM, or  
SLC®96.  
FMS1,FMS0:  
The FMS1 and FMS0 bits select standard superframe, T1DM, "alternate"  
T1DM, or SLC®96 framing formats. A logic 00 in these bits enable the SF  
framing format; a logic 01 in these bit positions enable the T1DM framing  
format; a logic 10 in these bit positions enable the SLC®96 framing format;  
and a logic 11 in these bit positions enable the "alternate" T1DM framing  
format.The "alternate" T1DM framing format configures the ALMI to process  
the RED ALARM as if the SF, SLC®96, or ESF framing format were selected;  
the YELLOW ALARM is still processed as T1DM.  
When ESF is selected (ESF bit set to logic 1), the FMS1 and FMS0 bits  
select the data rate and the source channel for the Facility Data Link (FDL)  
data. A logic 00 in these bits enables the ALMI to receive FDL data and  
validate the YELLOW alarm at the full 4 kbit rate. A logic 01 or 10 in these bits  
enables the ALMI to receive FDL data and validate the YELLOW alarm at a 2  
kbit rate.  