欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM4328-PI 参数 Datasheet PDF下载

PM4328-PI图片预览
型号: PM4328-PI
PDF下载: 下载PDF文件 查看货源
内容描述: 高密度T1 / E1成帧器,集成M13多路复用器 [HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED M13 MULTIPLEXER]
分类和应用: 复用器数字传输控制器电信集成电路电信电路异步传输模式ATM
文件页数/大小: 250 页 / 1399 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM4328-PI的Datasheet PDF文件第55页浏览型号PM4328-PI的Datasheet PDF文件第56页浏览型号PM4328-PI的Datasheet PDF文件第57页浏览型号PM4328-PI的Datasheet PDF文件第58页浏览型号PM4328-PI的Datasheet PDF文件第60页浏览型号PM4328-PI的Datasheet PDF文件第61页浏览型号PM4328-PI的Datasheet PDF文件第62页浏览型号PM4328-PI的Datasheet PDF文件第63页  
STANDARD PRODUCT  
PM4328 TECT3  
DATASHEET  
PMC-2011596  
ISSUE 1  
HIGH DENSITY T1/E1 FRAMER  
AND M13 MULTIPLEXER  
Pin Name  
Type Pin Function  
No.  
structure. Timing differences between the tributary  
timing and the synchronous SBI bus are indicated by  
adjustments of this payload indicator relative to the  
fixed SBI bus structure.  
All timing adjustments indicated by this signal are  
accompanied by appropriate adjustments in the SDPL  
signal.  
The TECT3 only drives the payload Indicator signal  
during the tributary timeslots assigned to this device.  
SDV5 is updated on the rising edge of SREFCLK.  
This signal shares a pin with IFP[28].  
SBIACT  
CLK52M  
Output A8  
Input P3  
SBI Output Active (SBIACT). The SBI Output Active  
indicator is high whenever the TECT3 is driving the SBI  
drop bus signals. This signal is used by other TECT3s  
or other SBI devices to detect SBI configuration  
problems by detecting other devices driving the SBI  
bus during the same tributary as the device listening to  
this signal.  
This output is updated on the rising edge or SREFCLK.  
52MHz Clock Reference (CLK52M). The 52Mhz clock  
reference is used to generate a gapped DS3 clock  
when receiving a DS3 from the SBI bus interface. This  
clock has two nominal values.  
The first is a nominal 51.84MHz 50% duty cycle clock.  
The second is a nominal 44.928MHz 50% duty cycle  
clock.  
When this clock is not used this input must be  
connected to ground.  
SBIDET[0]  
SBIDET[1]  
Input C8  
A7  
SBI Bus Activity Detection (SBIDET[1:0]). The SBI  
bus activity detect input detects tributary collisions  
between devices sharing the same SBI bus. Each SBI  
device driving the bus also drives an SBI active signal  
(SBIACT). This pair of activity detection inputs  
monitors the active signals from two other SBI devices.  
When unused this signal should be connected to  
ground.  
PROPRIETARY AND CONFIDENTIAL  
46  