PRELIMINARY  
PM4318 OCTLIU  
DATASHEET  
PMC- 2001578  
ISSUE 3  
OCTAL E1/T1/J1 LINE INTERFACE DEVICE  
Figure 16 – Serial PROM Command Format  
Reg[13:8]  
Reg[7:0]  
Data[7:0]  
Code1 Code0  
Reg[13:0] specifies one of the OCTLIU registers defined in Table 4. Data[7:0] is the value to be  
written to the specified register. Commands are interpreted depending on the Code1 and Code0  
bits as follows:  
Table 2  
– Serial PROM Commands – Code Bits  
Code1  
Code0  
Action  
0
0
1
1
0
1
0
1
Special Command  
Write Data[7:0] to Reg[13:0] only if SRCODE = 0  
Write Data[7:0] to Reg[13:0] only if SRCODE = 1  
Write Data[7:0] to Reg[13:0] regardless of value of  
SRCODE  
The SRCODE input to OCTLIU provides a means to execute configuration instructions  
conditionally. Two different configuration sequences can be stored in a single PROM (for T1 or  
E1 operation, for example) and the SRCODE input used to select which one will be applied.  
Different OCTLIU devices in a cascade can have their SRCODE inputs set to different values.  
When Code1 = Code0 = ‘0’, the Reg[13:0] and Data[7:0] fields are interpreted as a special  
command, not as a register/data pair. The following special commands are defined:  
Table 3  
– Serial PROM Special Commands  
Reg[13:0]  
3FFB  
Action  
Resume acting upon register write commands. Only meaningfull if a 3FFD  
command (see below) has previously been received.  
3FFC  
3FFD  
No-op.  
Ignore subsequent register write commands. This command is only acted  
upon by the first OCTLIU in the cascade which receives it and which is not  
already ignoring register write commands. The OCTLIU which acts upon this  
command does not propagate the command down the cascade, but instead  
substitutes the 3FFC special command.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
47