PRELIMINARY  
PM4318 OCTLIU  
DATASHEET  
PMC- 2001578  
ISSUE 3  
OCTAL E1/T1/J1 LINE INTERFACE DEVICE  
Pin Name  
Type  
Pin  
No.  
Function  
Timing Options Control  
XCLK  
Input  
D9  
Crystal Clock Input (XCLK). This signal provides a stable, global  
timing reference for the OCTLIU internal circuitry via an internal  
clock synthesizer. XCLK is a nominally jitter free clock at  
1.544 MHz in T1 mode and 2.048 MHz in E1 mode.  
In T1 mode, a 2.048 MHz clock may be used as a reference.  
When used in this way, however, the intrinsic jitter specifications  
in AT&T TR62411 may not be met.  
RSYNC/ICLK_OUT  
Output  
D8  
Recovered Clock Synchronization Signal (RSYNC). This output  
signal is the recovered, jitter attenuated, receiver line rate clock  
(1.544 or 2.048 MHz) of one of the eight T1 or E1 channels or,  
optionally, the recovered, jitter attenuated clock synchronously  
divided by 193 (T1 mode) or 256 (E1 mode) to create a 8 kHz  
timing reference signal. The default is to source RSYNC from  
octant #1.  
When the OCTLIU is in a loss of signal state, RSYNC is derived  
from the XCLK input or, optionally, is held high.  
RSYNC shares the same pin as the ICLK_OUT output. RSYNC is  
selected when SBI2CLK is tied low.  
Alarm Interface  
LOS  
Output  
A5  
Loss of Signal Alarm (LOS). This signal outputs the LOS status  
of the 8 LIU octants in a serial format which repeats every 8  
XCLK cycles. The presence of the LOS status for LIU #1 on this  
output is indicated by the LOS_L1 output pulsing high. On the  
following XCLK cycle, the LOS status for LIU #2 is output, then  
LIU #3, and so on.  
This signal is intended for use in Hardware Only mode. When the  
microprocessor interface is enabled, the status of the LOS alarm  
can also be determined by reading the LOSV bit in the CDRC  
Interrupt Status register.  
LOS is updated on the falling edge of XCLK.  
LOS_L1  
Output  
C7  
Loss of Signal LIU #1 indicator (LOS_L1). This signal is pulsed  
high for one XCLK cycle every 8 XCLK cycles and indicates that  
the LOS status for LIU #1 is being output on LOS.  
LOS_L1 is updated on the falling edge of XCLK.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  