欢迎访问ic37.com |
会员登录 免费注册
发布采购

TDA4841PS 参数 Datasheet PDF下载

TDA4841PS图片预览
型号: TDA4841PS
PDF下载: 下载PDF文件 查看货源
内容描述: I2C总线自动同步偏转控制器的PC显示器 [I2C-bus autosync deflection controller for PC monitors]
分类和应用: 显示器消费电路商用集成电路偏转集成电路光电二极管监视器控制器PC
文件页数/大小: 60 页 / 248 K
品牌: NXP [ NXP ]
 浏览型号TDA4841PS的Datasheet PDF文件第35页浏览型号TDA4841PS的Datasheet PDF文件第36页浏览型号TDA4841PS的Datasheet PDF文件第37页浏览型号TDA4841PS的Datasheet PDF文件第38页浏览型号TDA4841PS的Datasheet PDF文件第40页浏览型号TDA4841PS的Datasheet PDF文件第41页浏览型号TDA4841PS的Datasheet PDF文件第42页浏览型号TDA4841PS的Datasheet PDF文件第43页  
Philips Semiconductors  
Product specification  
I2C-bus autosync deflection controller for  
PC monitors  
TDA4841PS  
Protection and standby mode  
Soft-down sequence:  
L4  
Start the sequence by setting control bit SOFTST = 0  
BDRV duty cycle decreases  
S
8CH  
A
1AH  
A
00H  
A P  
HDRV duty cycle decreases.  
Soft-down sequence (XXXX XX00)  
Protection mode:  
STDBY = 0  
Pins HDRV and BDRV are floating  
Pins VOUT1 and VOUT2 are floating  
Continuous blanking on pin CLBL is active  
Pin HUNLOCK is floating  
SOFTST = 0  
Protection mode (XXXX XX00)  
STDBY = 0  
SOFTST = 0  
registers are set  
PLL1 and PLL2 are disabled  
Register contents are kept in internal memory.  
Protection mode can be left by 3 ways:  
no  
no  
STDBY = 1?  
yes  
SOFTST = 1?  
yes  
1. Entering standby mode by setting control  
bit SOFTST = 0 and bit STDBY = 1  
2. Starting the soft-start sequence by setting control  
bit SOFTST = 1 (bit STDBY = don’t care);  
see L3 of Fig.18 for continuation  
(1)  
L3  
S
8CH  
A
1AH  
A
01H  
A P  
3. Decreasing the supply voltage below 8.1 V.  
Standby mode:  
Standby mode (XXXX XX01)  
Set control bit STDBY = 1  
STDBY = 1  
SOFTST = 0  
all other register contents are random  
Driver outputs are floating (same as protection mode)  
Supply current is 9 mA  
Only the I2C-bus section and protection circuits are  
operative  
(1)  
L2  
MGL790  
Contents of all registers are lost, except the value of  
(1) See Fig.18.  
bit STDBY and bit SOFTST  
Fig.19 I2C-bus flow for standby mode and  
protection mode.  
See L2 of Fig.18 for continuation.  
1999 Oct 25  
39  
 复制成功!