16.3 Data slicer and data type control part  
The given values force the following behaviour of the SAA7114H VBI-data slicer part:  
Closed captioning data are expected at line 21 of field 1 (60 Hz/525 line system)  
All other lines are processed as active video  
Sliced data are framed by ITU 656 like SAV/EAV sequence (DID[5:0] = 3EH  
MSB of SAV/EAV = 1).  
Table 129 Data slicer start set-up values  
SUB  
ADDRESS  
(HEX)  
START VALUES  
FUNCTION  
slicer control 1  
BIT NAME(1)  
7 6 5 4 3 2 1 0 HEX  
40  
X, HAM_N, FCE, HUNT_N, X, X, X, X 0 1 0 0 0 0 0 0 00  
41 to 53 line control register 2 to 20  
54 line control register 21  
55 to 57 line control register 22 to 24  
LCRn_7 to LCRn_0 (n = 2 to 20)  
LCR21_7 to LCR21_0  
LCRn_7 to LCRn_0 (n = 22 to 24)  
FC7 to FC0  
1 1 1 1 1 1 1 1 FF  
0 1 0 1 1 1 1 1 5F  
1 1 1 1 1 1 1 1 FF  
0 0 0 0 0 0 0 0 00  
0 1 0 0 0 1 1 1 47  
0 0 0 0 0 1 1 0 06(2)  
1 0 0 0 0 0 1 1 83(2)  
58  
59  
5A  
5B  
programmable framing code  
horizontal offset for slicer  
vertical offset for slicer  
HOFF7 to HOFF0  
VOFF7 to VOFF0  
field offset and MSBs for  
FOFF, RECODE, X, VOFF8, X,  
HOFF10 to HOFF8  
horizontal and vertical offset  
5C  
5D  
reserved  
X, X, X, X, X, X, X, X  
0 0 0 0 0 0 0 0 00  
0 0 1 1 1 1 1 0 3E  
header and data identification  
code control  
FVREF, X, DID5 to DID0  
5E  
5F  
60  
61  
62  
sliced data identification code  
reserved  
X, X, SDID5 to SDID0  
0 0 0 0 0 0 0 0 00  
0 0 0 0 0 0 0 0 00  
read-only register  
X, X, X, X, X, X, X, X  
slicer status byte 1  
slicer status byte 2  
, FC8V, FC7V, VPSV, PPV, CCV, , −  
, , F21_N, LN8 to LN4  
LN3 to LN0, DT3 to DT0  
read-only register  
read-only register  
Notes  
1. All X values must be set to LOW.  
2. Changes for 50 Hz/625 line systems: subaddress 5AH = 03H and subaddress 5BH = 03H.  
2000 Mar 15  