欢迎访问ic37.com |
会员登录 免费注册
发布采购

ISP1362BD 参数 Datasheet PDF下载

ISP1362BD图片预览
型号: ISP1362BD
PDF下载: 下载PDF文件 查看货源
内容描述: 单芯片通用串行总线- The-Go的控制器 [Single-chip Universal Serial Bus On-The-Go controller]
分类和应用: 控制器
文件页数/大小: 150 页 / 621 K
品牌: NXP [ NXP ]
 浏览型号ISP1362BD的Datasheet PDF文件第82页浏览型号ISP1362BD的Datasheet PDF文件第83页浏览型号ISP1362BD的Datasheet PDF文件第84页浏览型号ISP1362BD的Datasheet PDF文件第85页浏览型号ISP1362BD的Datasheet PDF文件第87页浏览型号ISP1362BD的Datasheet PDF文件第88页浏览型号ISP1362BD的Datasheet PDF文件第89页浏览型号ISP1362BD的Datasheet PDF文件第90页  
ISP1362  
Single-chip USB OTG controller  
Philips Semiconductors  
Bit  
7
6
5
4
3
2
1
OCI  
0
0
Symbol  
Reset  
Access  
reserved  
LPS  
0
-
-
-
-
-
-
-
-
-
-
-
-
R
R/W  
Table 60: HcRhStatus register: bit description  
Bit  
Symbol  
Description  
31  
CRWE  
On writeClearRemoteWakeupEnable: Writing logic 1 clears  
DeviceRemoveWakeupEnable (DRWE). Writing logic 0 has no  
effect.  
30 to 18  
17  
-
reserved  
CCIC  
OverCurrentIndicatorChange: This bit is set by hardware when a  
change has occurred to the OverCurrentIndicator (OCI) eld of this  
register. The HCD clears this bit by writing logic 1. Writing logic 0  
has no effect.  
16  
LPSC  
On readLocalPowerStatusChange: The Root Hub does not  
support the local power status feature. Therefore, this bit is always  
read as logic 0.  
On writeSetGlobalPower: In the global power mode  
(PowerSwitchingMode = 0), logic 1 is written to this bit to turn on  
power to all ports (clear PortPowerStatus). In the per-port power  
mode, it sets PortPowerStatus only on ports whose  
PortPowerControlMask bit is not set. Writing logic 0 has no effect.  
15  
DRWE  
On readDeviceRemoteWakeupEnable: This bit enables the  
bit ConnectStatusChange as a resume event, causing a state  
transition from USBSuspend to USBResume and setting the  
ResumeDetected interrupt.  
0 ConnectStatusChange is not a remote wake-up event  
1 ConnectStatusChange is a remote wake-up event  
On writeSetRemoteWakeupEnable: Writing logic 1 sets  
DeviceRemoveWakeupEnable. Writing logic 0 has no effect.  
14 to 2  
1
-
reserved  
OCI  
OverCurrentIndicator: This bit reports overcurrent conditions  
when global reporting is implemented. When set, an overcurrent  
condition exists. When cleared, all power operations are normal. If  
per-port overcurrent protection is implemented, this bit is always  
logic 0.  
0
LPS  
On readLocalPowerStatus: The Root Hub does not support the  
local power status feature. Therefore, this bit is always read as  
logic 0.  
On writeClearGlobalPower: In the global power mode  
(PowerSwitchingMode = 0), logic 1 is written to this bit to turn off  
power to all ports (clear PortPowerStatus). In the per-port power  
mode, it clears PortPowerStatus only on ports whose  
PortPowerControlMask bit is not set. Writing logic 0 has no effect.  
9397 750 12337  
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.  
Product data  
Rev. 03 06 January 2004  
86 of 150  
 复制成功!