ISP1362
Single-chip USB OTG controller
Philips Semiconductors
Table 62: HcRhPortStatus[1:2] register: bit description
Bit
Symbol
-
Description
31 to 21
20
reserved
PRSC
PortResetStatusChange: This bit is set at the end of the 10 ms
port reset signal. The HCD can write logic 1 to clear this bit.
Writing logic 0 has no effect.
0 — port reset is not complete
1 — port reset is complete
19
OCIC
PortOverCurrentIndicatorChange: This bit is valid only if
overcurrent conditions are reported on a per-port basis. This bit is
set when the Root Hub changes the PortOverCurrentIndicator
(POCI) bit. The HCD can write logic 1 to clear this bit. Writing
logic 0 has no effect.
0 — no change in PortOverCurrentIndicator (POCI)
1 — PortOverCurrentIndicator (POCI) has changed
18
PSSC
PortSuspendStatusChange: This bit is set when the full resume
sequence is complete. This sequence includes the 20 ms resume
pulse, LS EOP and 3 ms re-synchronization delay. The HCD can
write logic 1 to clear this bit. Writing logic 0 has no effect. This bit is
also cleared when ResetStatusChange is set.
0 — resume is not completed
1 — resume is completed
17
16
PESC
PortEnableStatusChange: This bit is set when hardware events
cause the PortEnableStatus (PES) bit to be cleared. Changes from
the HCD writes do not set this bit. The HCD can write logic 1 to
clear this bit. Writing logic 0 has no effect.
0 — no change in PortEnableStatus (PES)
1 — change in PortEnableStatus (PES)
CSC
ConnectStatusChange: This bit is set whenever a connect or
disconnect event occurs. The HCD can write logic 1 to clear this
bit. Writing logic 0 has no effect. If CurrentConnectStatus (CCS) is
cleared when a SetPortReset, SetPortEnable or SetPortSuspend
write occurs, this bit is set to force the driver to re-evaluate the
connection status because these writes should not occur if the port
is disconnected.
0 — no change in CurrentConnectStatus (CCS)
1 — change in CurrentConnectStatus (CCS)
Remark: If the DeviceRemovable[NDP] bit is set, this bit is set only
after a Root Hub reset to inform the system that the device is
attached.
15 to 10
-
reserved
9397 750 12337
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
Product data
Rev. 03 — 06 January 2004
88 of 150