K3HB-V  
BCD Output Timing Chart  
A REQUEST signal from a Programmable Controller or other external device is required to read BCD data.  
Single Sampling Data Output  
Continuous Data Output  
20-ms pulse min. (50 ms max.)  
REQ.  
MAX.MIN.  
REQ.  
MAX.MIN.  
DATA  
All data "High"  
Data 1  
Data 2  
40 ms  
DATA  
All data "High"  
All data "High"  
Data  
DATA  
VALID  
DATA  
VALID  
40 ms  
24 ms  
24 ms  
Approx.  
30 ms  
Approx.  
30 ms  
40 ms  
64 ms  
64 ms  
16 ms  
The data is set in approximately 30 ms from the rising edge of the  
REQUEST signal and the DATA VALID signal is output.  
When reading the data from a Programmable Controller, start  
reading the data when the DATA VALID signal turns ON.  
The DATA VALID signal will turn OFF 40 ms later, and the data will  
turn OFF 16 ms after that.  
Measurement data is output every 64 ms while the REQUEST signal  
remains ON.  
Note: If HOLD is executed when switching between data 1 and data  
2, either data 1 or data 2 is output depending on the timing of  
the hold signal. The data will not go LOW.  
REQ. (1)  
K3HB  
(1)  
Programmable  
REQ. (2)  
Controller  
K3HB  
(2)  
REQ. (3)  
DATA (including POL and  
OVER) and DATA VALID can  
be used in a wired OR.  
(1)  
(2)  
(3)  
DATA  
RUN, HH, H, PASS, L, and  
LL are always output, with or  
without a REQUEST signal.  
Do not used a wired OR  
connect for these signals.  
K3HB  
(3)  
DATA  
VALID  
(See note.)  
(See note.)  
(See note.)  
Note: Leave 20 ms min. between DATA VALID turning OFF and the REQUEST signal.  
Programmable Controller Connection Example Display Unit Connection Example  
Digital Indicator  
SYSMAC Programmable Controller  
Digital Indicator  
DC Input Unit  
Connector pin No. (See note.)  
Connector pin No. (See note.)  
1.COMMON  
1.COMMON  
COM  
2.1  
IN  
IN  
IN  
IN  
2.1  
3.2  
3.2  
10°  
10°  
4.4  
4.4  
5.8  
5.8  
23.DATA VALID  
24.RUN  
23.DATA VALID  
24.RUN  
IN  
IN  
To 101  
To 102  
Transistor Output Unit  
25.COMMON  
26.REQUEST  
25.COMMON  
Short-  
OUT  
26.REQUEST circuit  
+5 V  
+5 V  
240 Ω  
240 Ω  
240 Ω  
240 Ω  
30.RESET  
OUT  
30.RESET  
240 Ω  
240 Ω  
240 Ω  
240 Ω  
31.POLARITY  
(+/polarity)  
COM  
(0 V)  
31.POLARITY  
(+/polarity)  
SEC  
8
8
8
24 VDC  
M7E-01D@N2, 01H@N2  
<M7E Digital Display Unit>  
+24 V  
Note: The BCD output connector pin number is the D-sub connector pin number when  
the BCD Output Cable (sold separately) is connected. This number differs from  
the pin number for the Digital Indicator narrow pitch connector (manufactured by  
Honda Tsushin Kogyo Co., Ltd.).  
DC power  
supply  
0 V  
Refer to the following User's Manual for application precautions and other information required when using the Digital Indicator:  
K3HB-S/-X/-V/-H Digital Indicator User's Manual (Cat. No. N128)  
The manual can be downloaded from the following site in PDF format: OMRON Industrial Web http://www.fa.omron.co.jp  