K3HB-V
■ Main Functions
Measurement
Timing Hold
Normal
Sampling Hold
• Holds the measurement at the rising edge of the TIMING signal.
• Continuously performs measurement and always outputs based on
comparative results.
Input
Sampling hold value
Input
H comparative set value
Measurement value
Measurement value
Time
ON
TIMING
input
Time
OFF
H output
Peak-to-peak Hold
Peak Hold/Bottom Hold
• Measures the maximum (or minimum) value in a specified period.
• Measures the difference between the maximum and minimum val-
ues in a specified period.
Input
Peak hold value
Input
Peak-to-peak value
(b2−a2)
(b1−a1)
Measurement value
Measurement value
TIMING ON
b1
'b2
a1
'a2
Bottom hold value
Time
Time
ON
TIMING
input
OFF
input
OFF
Scaling
Previous Average Value Comparison
Scaling converts input signals in any way required before displaying
them. The values can be manipulated by shifting, inverting, or +/–
reversing.
Slight changes can be removed from input signals to detect only
extreme changes.
Display value
Display value
Display value 2
Display value 2
(
dsp.a2
)
(dsp.a2)
Display value 1
dsp.a1
Display value 1
dsp.a1
(
)
(
)
Input value 1 Input value 2
Input value 2
(inp.a2)
Input value 1
inp.a1
Input value
Input value
(inp.
a1)
(inp.
a2)
(
)
(Scaling)
(Reverse scaling)
Teaching
Settings for scaling can be made using the present measurement
values instead of inputting values with the SHIFT and UP Keys. This
is a convenient function for making settings while monitoring the
operating status, for calculating amounts by tare reduction (to
measure only the contents), or when the result should be zero but
the display is not zero for some reason.
Standby Sequence
Turns the comparative output OFF until the measurement value
enters the PASS range.
Average Processing
Average processing of input signals with extreme changes or noise
smooths out the display and makes control stable.
12