CJ2M-CPU3@/-CPU1@/-MD21@  
Function  
Description  
Function Blocks  
Standard programming can be encapsulated as function blocks.  
Languages in Function Block Definitions  
Ladder programming or structured text  
The program can be changed during operation (in MONITOR or PROGRAM mode), except for  
block programming areas.  
Online Editing  
Specified bits can be set or reset.  
Force-set/reset to the EM Area is enabled by specifying a start bank in parameter setting.  
Force-Set/Reset  
Differentiate Monitoring  
Data Tracing  
ON/OFF changes in specified bits can be monitored.  
The specified I/O memory data can be stored in the trace memory in the CPU Unit. The  
triggers can be set.  
Debugging  
The trace data can be uploaded during data tracing using CX-Programmer, which enables  
continuously logging the data by constantly uploading the trace data.  
Continuous Tracing  
Automatically starting tracing when operation Data tracing can be automatically started when operation is started (i.e., when the operating  
starts  
mode is changed from PROGRAM mode to MONITOR or RUN mode).  
Storing Location of Error when an Error Occurs  
The location and task number where execution stopped for a program error is recorded.  
The programs can be checked for items such as no END instruction and FALS/FAL errors at  
startup.  
Program Check  
A function is provided to store predefined error codes in CPU Unit, error information, and time  
at which the error occurred.  
Error Log  
CPU Error Detection  
CPU Unit WDT errors are detected.  
Errors can be generated for user-specified conditions: Non-fatal errors (FAL) and fatal errors  
(FALS).  
User-defined Failure Diagnosis  
Program section time diagnosis and program section logic diagnosis are supported (FPD  
instruction).  
Load OFF Function  
RUN Output  
This function turns OFF all outputs from Output Units when an error occurs.  
The RUN output from the CJ1W-PA205R turns ON while CPU Unit is in RUN mode or  
MONITOR mode.  
This function provides alarm information from Basic I/O Units that have load short-circuit  
protection.  
Basic I/O Load Short-circuit Detection  
Failure Point Detection  
The time and logic of an instruction block can be analyzes using the FPD instruction.  
This function indicates when the CPU Unit is on standby because all Special I/O Units and  
CPU Bus Units have not been recognized at the startup in RUN or MONITOR mode.  
CPU Standby Detection  
System FAL Error Detection This function generates a non-fatal (FAL) error when the user-defined conditions are met in  
(User-defined non-fatal error) program.  
Duplicate Refreshing Error  
Detection  
This function detects an error when an immediate refreshing Instruction in an interrupt task is  
competing with I/O refreshing of a cyclic task.  
Basic I/O Unit Error Detection This function detects the errors in Basic I/O Units.  
Backup Memory Error  
Detection  
This function detects errors in the memory backup of the user programs and parameter area  
(backup memory).  
Self-  
diagnosis  
and  
PLC Setup Error Detection  
This function detects setting errors in the PLC Setup.  
This function detects an error when there is an error in data exchange between the CPU Unit  
and a CPU Bus Unit.  
CPU Bus Unit Error Detection  
Restoration  
Non-fatal Error  
Detection  
Special I/O Unit Error  
Detection  
This function detects an error when there is an error in data exchange between the CPU Unit  
and a Special I/O Unit.  
Tag Memory Error Detection *13 This function detects errors in tag memory.  
This function detects an error when a battery is not connected to the CPU Unit or when the  
battery voltage drops.  
Battery Error Detection  
CPU Bus Unit Setting Error  
Detection  
This function detects an error when the model of a CPU Bus Unit in the registered I/O tables  
does not agree with the model that is actually mounted in the PLC.  
Special I/O Unit Setting Error This function detects an error when the model of a Special I/O Unit in the registered I/O tables  
Detection does not agree with the model of Unit that is actually mounted.  
Option Board Error Detection *13 This function detects the errors in Serial Option Board mounting status.  
Memory Error Detection  
This function detects errors that occur in memory of the CPU Unit.  
This function detects when an error occurs in data transfers between the Units mounted in  
Rack slots and the CPU Unit and detects when the End Cover is not connected to the CPU  
Rack or an Expansion Rack.  
I/O Bus Error Detection  
This function detects an error when the same unit number is set for two or more Units, the  
same word is allocated to two or more Basic I/O Units, or the same rack number is set for two  
or more Racks.  
Unit/Rack Number  
Duplication Error  
Fatal Error  
Detection  
Too Many I/O Points Error  
Detection  
This function detects an error when the total number of I/O points set in the I/O tables or the  
number of Units per Rack exceeds the specified range.  
This function detects an error when the number of Units in the registered I/O tables does not  
agree with the actual number of Units that is mounted, or an Interrupt Unit has been connected  
in the wrong position, i.e., not in slot 0 to 4.  
I/O Setting Error Detection  
*14.Supported only by the CJ2M-CPU3@.  