DC and AC parameters
M25P20
10
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 10. Operating Conditions
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply Voltage
2.7
–40
–40
3.6
85
V
Ambient Operating Temperature (Device Grade 6)
Ambient Operating Temperature (Device Grade 3)
TA
°C
125
Table 11. Data Retention and Endurance
Parameter
Condition
Device Grade 6
Min.
Max.
Unit
100,000
10,000
20
Erase/Program
Cycles
cycles per
sector
Device Grade 3
at 55°C
Data Retention
years
Table 12. Capacitance
Symbol
Parameter
Test Condition
Min.
Max.
Unit
COUT
CIN
Output Capacitance (Q)
VOUT = 0V
VIN = 0V
8
6
pF
pF
Input Capacitance (other pins)
1. Sampled only, not 100% tested, at TA=25°C and a frequency of 20MHz.
36/50