M25P20
Initial delivery state
8
Initial delivery state
The device is delivered with the memory array erased: all bits are set to 1 (each byte
contains FFh). The Status Register contains 00h (all Status Register bits are 0).
9
Maximum rating
Stressing the device above the rating listed in the Absolute Maximum Ratings" table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the Operating sections of
this specification is not implied. Exposure to Absolute Maximum Rating conditions for
extended periods may affect device reliability. Refer also to the Numonyx SURE Program
and other relevant quality documents.
Table 9.
Symbol
Absolute Maximum Ratings
Parameter
Min.
Max.
Unit
TSTG
VIO
Storage Temperature
–65
–0.6
150
4.0
°C
V
Input and Output Voltage (with respect to Ground)
VCC
VESD
Supply Voltage
–0.6
4.0
V
Electrostatic Discharge Voltage (Human Body model) (1)
–2000
2000
V
1. JEDEC Std JESD22-A114A (C1=100 pF, R1=1500 Ω, R2=500 Ω).
35/50